Truwater VX-S Series Packaged Cooling Tower (crossflow, single cell up to 650 HRT)
Original title Truwater VX-S Cooling Tower: VXS/002/2020
Truwater
Truwater's 2020 VX-S catalogue: CTI STD-201 certified induced draft crossflow, film filled FRP packaged cooling towers, single cell up to 650 HRT, with low-noise fans.
On this page
Overview
The catalogue presents the VX-S series as an induced draft, crossflow, film filled, FRP, rectangular multi-cell packaged cooling tower for equipment cooling, industrial process cooling and air conditioning. Thermal performance is certified to CTI standard STD-201. Single cell capacity reaches 650 HRT (refrigeration tons).
Design emphasis is on light weight and space saving, low-noise fans (L standard, plus S super low noise and U ultra low noise), a structure that optimises energy consumption and corrosion-resistant materials suited to cooling water. Drive can be V-belt and pulley or right-angle gear reducer. Structure material options are hot-dip galvanised steel (S), FRP (F), timber (T) or stainless steel (X).
The model code example is VX S 2220 A 1 L XXX, encoding structure material, nominal cell size, number of cells, internal piping (I), gear drive (G), additional items (A), modification or not CTI listed (M) and fan noise class. The catalogue gives outline and foundation drawings for single-cell towers, with motor output (for example 1.5 kW for 2220X and 3.0 kW for 2220Z), current and fan data in tables. The motor is a TEFC, outdoor, three-phase, 4-pole induction motor.
The catalogue is a product data sheet with selection table, dimensions and model coding; flow tables by wet bulb, range and approach come from the manufacturer's separate selection software.
Key points
- Single cell capacity is up to 650 HRT (refrigeration tons).
- Thermal performance is certified to CTI STD-201.
- Type: induced draft, crossflow, film filled, FRP, rectangular multi-cell packaged tower.
- Fan noise classes: L low (standard), S super low, U ultra low noise.
- Drive: V-belt and pulley or right-angle gear reducer; motor TEFC, outdoor, three-phase, 4-pole.
- Structure material options: HDG steel, pultruded FRP, timber or stainless steel.
- Example motor output: 1.5 kW for the 2220X and 3.0 kW for the 2220Z (3.3 and 6.1 A at 415 V).
- The model code encodes cell count, nominal cell size, structure material, internal piping, gear drive and fan noise class.
Using it in design
- When selecting a tower, convert the hall condenser water load to HRT and verify it from the certified CTI performance table at design wet bulb.
- On noise-limited sites, evaluate the S or U fan option together with the sound level limit.
- In corrosive or coastal environments, choose structure material (FRP or stainless) for aggressive air and water quality.
- For redundancy in a multi-cell arrangement, check remaining capacity when one cell is out of service.
- Pass cell weights and foundation drawings to structural design; consult the manufacturer for internal piping and balancing connections.
Who should read it
Mechanical designers selecting towers for condenser water circuits and specification writers.
Document contents
- Introduction
- Example of model definition
- Outline and foundation drawings (single cell)
- VX-S series range (dimensions, motor, fan, drive)
Publication details
- Authors
- Truwater
- Publisher
- Truwater
- Year
- 2020
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document