Technical guideFree to read2024

Visiontec Inrow Rack Cooling Series: Rating Data, 2024

Original title Visiontec Inrow Cooling Solutions, September 2024

Visiontec

Visiontec's 2024 brochure presents inrow rack cooling units from 10 to 60 kW (air-cooled DX and chilled water) with EC fans, N+1 redundancy and hot or cold aisle containment layouts.

On this page

Overview

The document is the 8-page 2024 product brochure of the Visiontec Inrow rack cooling series. The unit is a precision air conditioner that cools server racks directly at the source and operates independently of the rack; air circulation uses internal channels designed with computer-aided tools. The series covers 10 to 60 kW in air-cooled (DX) and chilled water versions and can be used in rooms with or without a raised floor and with hot or cold aisle containment.

The guide specification defines the construction: 10 and 20 kW models are 300 mm wide and 30 kW and above are 600 mm wide; electrical and piping connections are made from top or bottom and no side access is needed. The chilled water coil is controlled by a built-in modulating valve. Fans are backward-curved centrifugal fans with EC motors; with the N+1 option the unit runs at 75% airflow normally and the remaining fans speed up to 100% if one fails. DX models have a single scroll compressor, located outdoors on the 20 to 60 kW models so service does not require entering the data center.

Options include a water detection kit, heater, humidifier, inverter compressor, heat and smoke detector and PIBCV valves for chilled water. Modbus is built in; Lonworks, BACnet, SNMP and SMS are optional. The technical data table gives air-cooled (35 °C outdoor) and chilled water (6.7 °C entering water) capacities for the 10 to 60 kW models with fan, compressor, dimension and connection data. Nominal capacity is based on 37.0 °C / 21.4 °C, 23% RH.

Key points

  1. Capacity range is 10 to 60 kW; air-cooled DX and chilled water versions.
  2. Width is 300 mm for 10 and 20 kW models and 600 mm for 30 kW and above; depth about 1000 mm and height about 2000 mm.
  3. Nominal capacity is based on 37.0 °C / 21.4 °C, 23% RH entering air; air-cooled performance is at 35 °C outdoor and chilled water performance at 6.7 °C entering water.
  4. Backward-curved fans with EC motors; with N+1 the normal duty is 75% airflow and the remaining fans go to 100% on a failure.
  5. DX models have a single scroll compressor; on 20 to 60 kW models it is in the outdoor unit.
  6. Coils are hydrophilic-coated aluminium fin on seamless copper; the electric reheat is two-stage.
  7. Modbus is built in with dry contacts for DCIM and fire alarm; Lonworks, BACnet, SNMP and SMS are optional.
  8. Fits rack densities of 10 to 60 kW; hot or cold aisle containment layouts are supported.

Using it in design

  • Consider inrow cooling for 10 to 60 kW rack densities in contained-aisle layouts for close-coupled cooling; carry the 300 mm and 600 mm widths into row length planning.
  • Take nominal capacity at 37.0 °C entering air and 23% RH; if your design condition differs, ask the manufacturer for a new selection.
  • For 20 to 60 kW DX models, include the outdoor unit location and refrigerant pipe distances in the layout; the outdoor compressor reduces maintenance entries into the hall.
  • Include N+1 fan redundancy and monitoring (Modbus, BACnet, SNMP) integration in the DCIM design.
  • On chilled water models add the PIBCV option and water detection kit to the hydraulic and safety design.

Who should read it

Data center mechanical designers and operators selecting inrow cooling for medium- and high-density racks.

Document contents

  1. Inrow rack cooling unit introduction and features
  2. Installation and options
  3. Guide specifications (general, cabinet, coil, fan, compressor, filters, drain pan, electric reheat, condensing section)
  4. Dimension and layout drawings
  5. Inrow cooling series technical data

Publication details

Authors
Visiontec
Publisher
Visiontec
Year
2024
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Visiontec (2024). Visiontec Inrow Cooling Solutions, September 2024. Visiontec. https://pavision.com.my/images/2024/VS_Inrow_V3_sept2024.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.