Yantai Moon Semi-Hermetic Compressor Water Chiller Unit, Technical parameters
Yantai Moon
Yantai Moon LSBLGF semi-hermetic screw water chillers use R22 and cover 116-2320 kW; the table is based on 30°C condenser inlet and 7°C chilled water outlet.
On this page
Overview
The LSBLGF series is presented as a complete set of equipment providing chilled water for air conditioning or industrial refrigeration. The motor uses a semi-hermetic screw refrigeration compressor and the refrigerant is R22 with water as the cooled medium. The table lists 19 models running on 380 V 3N~50 Hz.
Model capacities run from LSBLGF116 (116 kW) to LSBLGF2320Ⅳ (2320 kW); examples are 175 kW for LSBLGF175, 410 kW for LSBLGF410 and 1160 kW for LSBLGF1160Ⅱ. The capacity control range is 30-100% on single-compressor models and falls to 8-100% on the largest multi-compressor models (for example LSBLGF2320Ⅳ); the power column runs from 30 kW (LSBLGF116) to 132 x 4 kW (LSBLGF2320Ⅳ) and is written as the sum of compressor powers on multi-compressor models (for example 100x2+132).
The table note states the design conditions: condenser cooling water inlet +30°C with 5°C inlet-outlet difference; chilled water outlet 7°C with 5°C inlet-outlet difference. Listed features are a new high-efficiency semi-hermetic screw compressor, high machining precision, low noise, high-efficiency heat-exchange tubes, a Danfoss expansion valve controlling liquid supply, a programmable controller and a compact, light structure.
Key points
- LSBLGF series semi-hermetic screw water chillers; refrigerant R22; supply 380 V 3N~50 Hz.
- Capacity runs from 116 kW (LSBLGF116) to 2320 kW (LSBLGF2320Ⅳ).
- Capacity control range is 30-100% down to 8-100% on large models.
- Power in the table runs from 30 kW to 132x4 kW; multi-compressor models list the sum.
- Design conditions: condenser water inlet 30°C, difference 5°C; chilled water outlet 7°C, difference 5°C.
- A Danfoss expansion valve controls liquid supply and outlet temperature accuracy.
- A programmable controller and inlet control element are standard features.
Using it in design
- Compare capacities only at 30°C condenser inlet and 7°C chilled water outlet; request corrections from the manufacturer for other conditions.
- Read the table power as compressor input and add pumps and tower for total plant power.
- For part-load operation compare the capacity control range (8-100% or 30-100%) with the load profile.
- Verify the suitability of R22 for the project against current refrigerant regulation and service access.
Who should read it
Mechanical designers comparing medium and large water-cooled screw chillers.
Document contents
- Semi-Hermetic Compressor Water Chiller Unit
- Technical parameters
- Features
- Related products
Publication details
- Authors
- Yantai Moon
- Publisher
- Yantai Moon
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Yantai Moon Yantai Moon Semi-Hermetic Compressor Water Chiller Unit, Technical parameters. Yantai Moon. https://freezingsolution.com/1-3-2-water-chiller-unit/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.