Factors affecting the energy consumption of data centres in South Africa

University of Pretoria · Daleela Young

A 2008 MBA dissertation at the University of Pretoria uses 19 interviews to gauge South African organisations' data-centre energy awareness; consolidation emerges as the main factor and cost as the main motive.

On this page

Overview

Daleela Young's MBA dissertation starts from the observation that, unlike companies in the US and UK seeking ways to avoid high future data-centre costs, South Africa lacks space shortages and high energy costs, so energy efficiency is not yet a priority. The study examines three questions: awareness of data-centre energy consumption, the factors perceived to cause fluctuations in consumption, and the motivation to act.

The method is semi-structured interviews: sixteen telephonic and three face-to-face, 19 in total. Interviewees were drawn from the 2005/6 list of top ICT companies in South Africa, ITWEB Green IT Summit 2008 attendees and referrals. The sample covers banking, retail and energy; the government sector was left out because of access. The author accepts that the sample may be seen as small and explains this by South Africa's small market and low response rates.

The findings are that data-centre energy efficiency is not yet a priority for South African organisations and local companies are busy with other matters, while data-centre managers of global organisations appear more confident on measurement and awareness. Literature cites planned and unplanned business demand as the main factor, whereas interviewees stressed data-centre consolidation. On the IT management side, server consolidation and virtualisation are the top factors, in line with literature. In motivation, money is still the top decision criterion.

The conclusion argues that data-centre management, IT and building facilities teams must measure energy across organisational silos and that IT costs should be judged on full life-cycle cost. The study dates from 2008 and is perception-based: it contains no facility-level energy measurements, so it is useful for the context of organisational awareness and decision making rather than for current facility metrics.

Key points

  1. The study rests on 19 semi-structured interviews: 16 telephonic and 3 personal (including the Central Energy Fund and two IBM stakeholders).
  2. The sample covers banking, retail and energy; the government sector is excluded.
  3. 56% of respondents said total organisational energy consumption had increased over the previous twelve months.
  4. Data-centre energy consumption is not a priority at local companies; local managers of global organisations are more confident on measurement.
  5. Literature names planned and unplanned business demand as the main factor, but interviewees saw data-centre consolidation as the most important.
  6. On IT management, server consolidation and virtualisation stand out as the top factors for energy efficiency.
  7. Money (cost) is the top motivation in decisions; many participants admit not investigating options closely.
  8. The author recommends that IT management account for the energy cost of equipment decisions and that units measure energy across silos.

Using it in design

  • Ask in which budget energy cost appears for the client or stakeholders; if IT and facilities budgets are separate, energy-saving investments may not surface.
  • Include the effect of IT decisions such as consolidation and virtualisation on facility power and cooling in the capacity plan.
  • Frame the investment case on cost first and show full life-cycle cost including energy.
  • Design shared metering points and joint reporting for facility and IT rather than separate measurement.
  • Use this study as context on awareness and decision-making, not as a numerical design input.

Who should read it

Data-centre investors, consultants preparing energy-efficiency proposals in emerging markets, and corporate IT and facilities managers.

Document contents

  1. Introduction to the research problem
  2. Theory and literature review
  3. Research questions
  4. Research methodology
  5. Results
  6. Discussion of results
  7. Conclusion

Publication details

Authors
Daleela Young
Publisher
University of Pretoria
Year
2008
Document number
MBA dissertation
Document language
English
Source type
Scientific
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official university repository and PDF inspected. Copyright University of Pretoria; no document-specific commercial reuse licence established. Repository date/citation discrepancy preserved.

Citation

Daleela Young (2008). Factors affecting the energy consumption of data centres in South Africa. University of Pretoria. MBA dissertation. https://repository.up.ac.za/items/67a60b16-dc2d-4151-a893-6431cefcad9d

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.