2019 ASHRAE Handbook-HVAC Applications, Chapter 20: Data Centers and Telecommunication Facilities
ASHRAE · ASHRAE TC 9.9
The data centre chapter of the 2019 ASHRAE Handbook, covering datacom equipment, environmental guidelines, economizer types and the Datacom Series book list.
On this page
Overview
This document is Chapter 20 of the 2019 edition of the ASHRAE Handbook-HVAC Applications, devoted to data centres; the 2023 edition is already in the library. It is authored by ASHRAE TC 9.9 and covers datacom equipment, environmental guidelines and economizers. It also lists Datacom Series Books 1-13 with editions and years, for example Book 2, IT Equipment Power Trends, 3rd edition, 2018.
The economizer section describes direct and indirect air-side economizers and pumped refrigerant-side economizers. It defines wet, dry and hybrid economizers, where a hybrid can be tuned to optimise either water or power use. For water-side economizers, the heat exchanger is recommended in series with the chiller to maximise economizer hours. These definitions give a shared vocabulary for comparing economizer options on water use, energy use and climate.
The bibliography cites TC 9.9 white papers: 2011 contamination, 2012 IT thermal management and controls, and 2014 networking equipment.
Key points
- Lists Datacom Series Books 1-13 with editions and years (e.g. Book 2, IT Equipment Power Trends, 3rd ed. 2018).
- Describes direct and indirect air-side economizers and pumped refrigerant-side economizers.
- Defines wet, dry and hybrid economizers; hybrid can optimise either water or power use.
- Recommends the water-side economizer heat exchanger in series with the chiller to maximise economizer hours.
- Bibliography cites TC 9.9 white papers: 2011 contamination, 2012 IT thermal management and controls, 2014 networking equipment.
- This is the 2019 edition; the 2023 edition is a separate library entry.
Using it in design
- Cite cooling design rules in an edition-aware way, distinguishing the 2019 and 2023 Handbook editions.
- When selecting economizers, evaluate direct, indirect and pumped refrigerant-side options together with the wet, dry and hybrid classification.
- When designing a water-side economizer, treat placing the heat exchanger in series with the chiller as the default for maximising economizer hours.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Check cooling capacity alongside your design
Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.
Request a demo
Who should read it
Mechanical engineers designing data centre cooling and consultants who cite ASHRAE references.
Related standards
- ANSI/ASHRAE 90.4-2016
- ANSI/ASHRAE 127-2012
- ANSI/TIA-942-B
Publication details
- Authors
- ASHRAE TC 9.9
- Publisher
- ASHRAE
- Year
- 2019
- Document number
- HVAC Applications 2019 Ch. 20
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Copyrighted ASHRAE book sold via ASHRAE Bookstore (and TC 9.9 Datacom Encyclopedia subscription). Not read; metadata from ASHRAE catalogue / Handbook descriptions only. Citation only.
Citation
ASHRAE TC 9.9 (2019). 2019 ASHRAE Handbook-HVAC Applications, Chapter 20: Data Centers and Telecommunication Facilities. ASHRAE. HVAC Applications 2019 Ch. 20. https://handbook.ashrae.org/Handbooks/A19/SI/a19_ch20/a19_ch20_si.aspx
Events on this subject
- ISK-SODEX Istanbul 2027
- SC26 – International Conference for High Performance Computing, Networking, Storage and Analysis
- ASHRAE Winter Conference
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.