StandardCitation2016

IEC 60909-0:2016 - Short-circuit currents in three-phase a.c. systems - Part 0

Original title IEC 60909-0:2016 — Short-circuit currents in three-phase a.c. systems — Part 0

IEC · IEC TC 73

IEC 60909-0:2016 is the pinned calculation-method edition for short-circuit currents in three-phase a.c. systems; the SoSo CAD implementation covers only a restricted LV radial balanced-fault subset.

On this page

Overview

This record identifies Edition 2.0 (2016) of IEC 60909-0, prepared by IEC TC 73. The standard concerns short-circuit currents in three-phase a.c. systems, and it is held here to pin the identity of the calculation-method edition. The record was retrieved on 2026-11-12.

According to the record, the 2016 edition includes 50 Hz and 60 Hz three-phase LV short-circuit calculations. The local implementation, however, does not cover the whole standard: it provides an explicitly bounded LV radial three-phase screen, which is only a restricted radial balanced-fault subset. The fault types and network structures the standard treats are therefore not all within the implementation's scope.

The record states two important limits. First, IEC lists a 2026 successor, and this entry does not establish conformance to that successor. Second, it does not establish current national adoption either. The record is therefore not a conformance statement but a traceable description of which edition the work follows. The practical consequence for a designer: the short-circuit screen can be useful for quick preliminary assessment and for selectivity and breaking-capacity checks, but for structures outside its scope (for example non-radial or unbalanced faults), and in projects needing formal conformance, the full text of the standard and a detailed calculation are required.

Key points

  1. Standard: IEC 60909-0:2016, Edition 2.0, prepared by IEC TC 73; paid, only metadata used.
  2. The 2016 edition includes 50 Hz and 60 Hz three-phase LV short-circuit calculations.
  3. The local implementation covers only a restricted radial balanced-fault subset.
  4. The implementation is an explicitly bounded LV radial three-phase screen.
  5. IEC lists a 2026 successor; this entry does not establish conformance to it.
  6. The entry also does not establish current national adoption.

Using it in design

  • Use the short-circuit screen as a quick preliminary assessment and as a first step in selectivity and breaking-capacity checks.
  • Do not rely on the screen for non-radial networks and unbalanced faults; run a detailed calculation.
  • State in reports which edition (2016) was followed and do not claim conformance to the 2026 successor.
  • For projects requiring formal conformance, consult the full text and the national adoption.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Review your power design in SoSo CAD

Inspect supply paths, equipment loads and UPS failure scenarios in one model.

Request a demo
Single-line diagram in the SoSo CAD power and capacity workspace

Who should read it

Electrical designers doing LV short-circuit calculations and developers documenting the scope of a calculation tool.

Publication details

Authors
IEC TC 73
Publisher
IEC
Year
2016
Edition
2.0
Document language
English
Source type
Standard
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document