Accelsius NeuCool MR250 Specifications
Original title NeuCool MR250 product specifications
Accelsius
Accelsius NeuCool MR250 is a two-phase, row-based direct-to-chip cooling CDU giving up to 250 kW for 1-4 racks, with 1+1 redundant pumps and a maximum system input of 2.6 kW.
On this page
Overview
Accelsius presents the NeuCool MR250 as the industry's first two-phase, row-based CDU. The unit provides up to 250 kW of liquid cooling capacity for large-scale deployments of high-density racks. A reservoir supplies inlet pressure for the pumps and expansion volume for transients from zero to full power; a brazed plate heat exchanger condenses refrigerant vapour and transfers heat to the facility water loop, with the facility water connection at top-rear, bottom-rear or through the bottom.
Configurations include 1×250 kW rack, 2×125 kW rack and warm rack expansions. The system supports two dielectric refrigerants: Eco+ (R-1233zd(E)) and Performance+ (R-515B), both with zero ODP, low GWP and an A1 safety rating. Pumps (1+1 redundant with automatic switchover on failure), power supplies and control boards are hot-swappable. The specification table gives 250 kW total cooling capacity and 2.6 kW maximum system input.
Key points
- Up to 250 kW of two-phase cooling capacity; 1×250 kW or 2×125 kW rack configuration.
- Maximum system input is 2.6 kW.
- Two pumps 1+1 redundant; automatic pump switchover.
- Refrigerant options R-1233zd(E) (Eco+) and R-515B (Performance+); ODP 0, A1.
- 15-inch NeuView touchscreen with DCIM integration.
Using it in design
- The table supports one or two racks while the introductory copy mentions four; confirm the project configuration with the manufacturer.
- Assess facility water temperature separately for the rated and derated compatibility ranges.
- Hot-swappable pumps, power supplies and control boards shorten service time in the redundancy scheme.
- Choose the refrigerant (R-1233zd(E) or R-515B) by GWP and safety class requirement.
Who should read it
Liquid-cooled data-centre designers evaluating two-phase direct-to-chip cooling.
Publication details
- Authors
- Accelsius
- Publisher
- Accelsius
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Accelsius NeuCool MR250 product specifications. Accelsius. https://accelsius.com/single-product-mr250/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.