Technical guideFree to read2021

Fan Engineering II (Aironn Technical Publications No. 2)

Original title Fan Mühendisliği – II

Aironn Havalandırma · Suat Canbazoğlu

A 412-page second volume by Prof. Dr. Suat Canbazoğlu, published by Aironn in December 2021, covering fan accessories and drives, materials and structural calculations, ErP and FEI standards and fan performance testing.

On this page

Overview

The second volume of the Fan Engineering series contains chapters 9 to 12 and complements the theoretical base of volume one with practice, standards and testing. The four chapters are accessories and drive systems used with fans, fan materials and basic structural calculations, fan standards, and fan performance tests. The book is written in Turkish and was first printed in December 2021.

The accessories chapter covers inlet and outlet connections, inlet and outlet dampers and actuators, dissipative and reactive silencers, variable speed control and drives, and bearings (plain and rolling-element bearings, lubrication, bearing life, housings and seals). The materials chapter covers fan material selection and basic structural calculations.

In the standards chapter, energy-related standards come in two groups: the EU Commission Regulation 327/2011 (30 March 2011) under ErP, and in the USA AMCA 208-18 (Fan Energy Index calculation), AMCA 207-17 and AMCA 211-13. FEI is described as addressing both fan design and application (sizing and selection) and as usable by regulators, utilities, code bodies and purchasing agents. AMCA fan classes, ISO fan performance standards and the ANSI/AMCA 210-07 / ANSI/ASHRAE 51-07 certified aerodynamic performance test are also here.

The last chapter covers fan performance testing: density determination, static, dynamic and total pressure measurement, flow measurement with measurement grids (rectangular and circular sections), indirect and direct flow methods and speed measurement (stroboscope, optical). The book is a general fan engineering reference with no data-center-specific section, but it serves for fan selection, acceptance testing and energy regulation.

Key points

  1. Four chapters: accessories and drives (9), materials and structural calculations (10), standards (11), performance tests (12); 412 pages.
  2. The accessories chapter includes dampers, actuators, silencers, variable speed drives, bearings and bearing life.
  3. Silencers are divided into dissipative (absorptive) and reactive types.
  4. Energy standards: EU Regulation 327/2011 (30 March 2011) under ErP; in the USA AMCA 208-18 (FEI), AMCA 207-17 and AMCA 211-13.
  5. FEI addresses both fan design and application (sizing and selection) and can be used by regulators, utilities, code bodies and purchasing agents.
  6. Performance standards include ISO standards and the ANSI/AMCA 210-07 / ANSI/ASHRAE 51-07 certified aerodynamic performance test.
  7. The testing chapter covers pressure, density, flow (measurement grids, indirect and direct methods) and speed measurement.
  8. AMCA fan classes are given by discharge position, drive and arrangement, and maximum system static pressure and outlet velocity.

Using it in design

  • In CRAH, dry cooler and ventilation fan specifications, state the energy standard to be met (327/2011, FEI) and the operating point at which it is evaluated.
  • Request fan performance acceptance tests to ANSI/AMCA 210 or the relevant ISO standard, with certified laboratory data.
  • Evaluate variable speed drive, damper and silencer selection together with the fan's operating range and noise target.
  • Include bearing type, lubrication and bearing life in the maintenance plan and spare parts list.
  • When measuring fan flow on site, follow the standard's layout for the section, measurement grid and flow straighteners.

Who should read it

HVAC and mechanical engineers who write fan specifications and assess performance testing and energy regulation compliance.

Document contents

  1. Accessories and Drive Systems Used with Fans
  2. Fan Materials and Basic Structural Calculations
  3. Fan Standards (ErP, FEI, AMCA classes, performance standards)
  4. Fan Performance Tests

Publication details

Authors
Suat Canbazoğlu
Publisher
Aironn Havalandırma
Year
2021
Document number
AIRONN Teknik Yayınlar No. 2; ISBN 978-975-6263-52-5
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public manufacturer documentation inspected. No redistribution permission established. Metadata and original brief summaries only; local downloads are research evidence, not a redistribution package.

Citation

Suat Canbazoğlu (2021). Fan Mühendisliği – II. Aironn Havalandırma. AIRONN Teknik Yayınlar No. 2; ISBN 978-975-6263-52-5. https://www.aironn.com.tr/upload/article/23/199892-aironn_teknik-bu-lten-cilt-2-du-s-u-k.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.