Data Center Sustainability Guide: Transforming Your Data Center with Sustainable Cooling Solutions

Alfa Laval

Alfa Laval's eBook sets out the business case for liquid cooling, free cooling and heat recovery; the publisher claims up to 27% lower OPEX and 30% lower energy use.

On this page

Overview

Alfa Laval's public page presents its data centre sustainability guide eBook. According to the page, data demand is growing rapidly, traditional cooling systems are expensive and inefficient, and innovative cooling technology aims to meet rising power demand and sustainability requirements together. The guide covers the effect of investing in technologies such as liquid cooling and heat recovery on operating expenditure (OPEX) and energy use.

The figures the publisher puts forward are: liquid cooling and heat recovery can reduce OPEX by up to 27% and energy consumption by 30%; data centres consume 1-1.5% of global electricity; free cooling systems lower cooling energy by up to 30%. These numbers are the publisher's promotional claims. The eBook also describes the business case for upgrading cooling technology and the long-term return on investment.

Key points

  1. Publisher: Alfa Laval; subject is sustainable data centre cooling and its business case.
  2. Scope: liquid cooling, free cooling and heat recovery.
  3. Publisher claim: liquid cooling and heat recovery can cut OPEX by up to 27% and energy consumption by 30%.
  4. Publisher claim: free cooling systems lower cooling energy by up to 30%.
  5. The publisher states that data centres consume 1-1.5% of global electricity.

Using it in design

  • Do not enter the publisher's claims (OPEX 27%, energy 30%) into a business case without recalculating with your own climate, load and electricity price data.
  • Establish annual suitable hours for free cooling and the heat recovery off-taker at the start of the project.
  • Evaluate a liquid cooling investment together with operating cost, return on investment and regulatory sustainability requirements.

Who should read it

Data centre operators and decision makers preparing a business case for a cooling technology upgrade.

Publication details

Authors
Alfa Laval
Publisher
Alfa Laval
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Publisher landing page opened; it routes delivery to the reader's inbox and displays ©2015–2024 ALFA LAVAL plus legal-terms link. No open licence. Full eBook not accessed and publication year not established.

Citation

Alfa Laval Data Center Sustainability Guide: Transforming Your Data Center with Sustainable Cooling Solutions. Alfa Laval. https://www.alfalaval.us/campaign/data-center-cooling-technology-sustainability-guide/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.