A Data Center Primer for Water Service Providers

Alliance for Water Efficiency · J. DeCotis Smith, J. Hick et al.

A June 2026 primer from the Alliance for Water Efficiency, with Los Alamos National Laboratory and the Metropolitan North Georgia Water Planning District, on involving water utilities early in data-centre planning.

On this page

Overview

The Alliance for Water Efficiency (AWE) released this primer in June 2026 together with Los Alamos National Laboratory and the Metropolitan North Georgia Water Planning District. It is aimed at water utilities and other water practitioners who want to take part effectively in the planning and design of data-centre projects in their communities, and it combines technical background with practical guidance.

The publication responds to growing concern about data-centre water use, missed opportunities for water efficiency and reuse, and cases where water service providers were left out of key planning and design discussions. According to the publisher, even highly efficient data centres can place significant demands on local supplies, so early and informed involvement is essential.

The content is organised around four topics: data-centre types and functions, cooling technologies, how much water data centres use, and how to make sure water is properly considered during development. The primer includes a Data Center Coordination Workbook made of fillable PDF forms that walk water providers through the recommended coordination process.

Key points

  1. Released in June 2026 by AWE with Los Alamos National Laboratory and the Metropolitan North Georgia Water Planning District.
  2. Scope: data-centre types and functions, cooling technologies, water use, and including water in the development process.
  3. Early involvement of water service providers in planning and design discussions is the central message.
  4. Even highly efficient facilities can create significant demand on local water supplies.
  5. A companion Coordination Workbook uses fillable PDF forms to structure the coordination process.
  6. The full text is available to AWE members; non-members can request a copy.

Using it in design

  • Add the local water utility to the stakeholder list at project start and share average and peak water demand early.
  • Assess the cooling technology choice (dry, evaporative, hybrid) together with water-demand scenarios.
  • Investigate water reuse and efficiency options at concept stage, before infrastructure decisions are fixed.
  • Use the workbook logic as a checklist for data exchange with the water utility.

Who should read it

Water utilities, data-centre developers and design engineers coordinating site selection and water infrastructure.

Publication details

Authors
J. DeCotis Smith; J. Hick; C. Benoit; Tala; C. Booton; J. Hughes; D. Foster Smith
Publisher
Alliance for Water Efficiency
Year
2026
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public announcement dated 23 June 2026 inspected; suggested citation says June 2026. Full document is member/request-access. No licence or full-text permission established.

Citation

J. DeCotis Smith; J. Hick; C. Benoit; Tala; C. Booton; J. Hughes; D. Foster Smith (2026). A Data Center Primer for Water Service Providers. Alliance for Water Efficiency. https://allianceforwaterefficiency.org/data-center-primer-for-water-service-providers/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.