Rethinking physical security in the data center era: for hyperscale and colocation environments
Original title Rethinking physical security in the data center era: For hyperscale and colocation environments
Axis Communications
An Axis e-brochure presenting a five-layer defence-in-depth model for data centres (perimeter, premises, buildings, server halls, racks) with edge analytics, thermal detection and cyber measures such as TPM 2.0 and secure boot.
On this page
Overview
The brochure states that data centre capacity demand is projected to triple by 2030 and that spending on security and fire protection systems is expected to grow at a 17 percent CAGR through 2030. Its core claim is that physical security should not be an afterthought but core facility infrastructure planned and funded alongside power, cooling and connectivity.
The five-layer defence model comprises perimeter, premises, buildings, server halls and server racks. The outer layers use IP video, thermal cameras, radar, edge analytics, licence plate recognition and drone detection. Buildings and server halls add access control, biometric authentication and anti-tailgating, multi-sensor PTZ cameras and temperature anomaly and smoke detection. The rack layer covers cabinet-level access monitoring, internal cameras and temperature monitoring.
The operational efficiency section stresses fewer false alarms, remote verification and centralised multi-site monitoring. The cybersecurity section addresses supply chain attacks and cites a hardware-based security platform, TPM 2.0, signed OS, secure boot and a security notification service. The sustainability section states that the facility infrastructure (cooling and security) market is projected to reach 106 billion dollars by 2030 and that 80 percent of products are PVC-free. A Moro Hub case in Dubai illustrates the layers in practice.
The document is a manufacturer e-brochure: product features and benefits are vendor claims with no independent measurements. For designers, its value is raising early inclusion of physical security layers in facility planning and integration with BMS, fire and cooling systems.
Key points
- Data centre capacity demand is projected to triple by 2030; security and fire protection spending is projected to grow at 17 percent CAGR.
- Five layers: perimeter, premises, buildings, server halls and server racks.
- The perimeter uses IP video and thermal cameras with edge analytics; premises and buildings add radar, PTZ cameras, drone detection and plate recognition.
- Server halls use biometric authentication, anti-tailgating, thermal and smoke detection, with alerts passed to cooling and backup generator systems.
- The rack layer provides cabinet-level access monitoring, internal 5 MP video and temperature monitoring.
- For supply chain attacks it highlights TPM 2.0, signed OS and secure boot, with remote checks that software is up to date.
- The facility infrastructure (cooling and security) market is projected to reach 106 billion dollars by 2030.
- 80 percent of products are PVC-free; edge analytics and Zipstream reduce data and bandwidth.
Using it in design
- Plan physical security with the five-layer model and add detection and access control points for each layer to the facility plan early.
- At server hall entrances, design biometric authentication and anti-tailgating, and record tenant separation in multi-tenant areas.
- Define interface points to integrate camera and thermal detection alerts with BMS, fire and cooling systems.
- Specify supply chain measures such as TPM, signed software and secure boot for networked security devices and reserve a separate network segment for device management.
- Include camera and storage power and data volume in the energy budget.
Who should read it
Architects, security engineers and facility operations managers designing physical security for hyperscale and colocation data centres.
Document contents
- Introduction: the data revolution and the security imperative
- Protecting your most valuable asset
- 5-layer defense strategy
- Operational efficiency
- Cybersecurity: protection against supply chain attacks
- Sustainability: the value of minimizing energy use
- Axis in action: the Moro Hub partnership
- Recommended solutions
Publication details
- Authors
- Axis Communications
- Publisher
- Axis Communications
- Year
- 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.
Citation
Axis Communications (2026). Rethinking physical security in the data center era: For hyperscale and colocation environments. Axis Communications. https://www.axis.com/dam/public/permalink/129329/ebrochure--data-centers-en-US_129329.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.