Secure Firmware Recovery, Version 1.1
Open Compute Project · Eric Spada (editor), Varun Sampath (editor) et al.
An OCP specification defining a protocol for recovering corrupted device firmware over SMBus, I3C and USB. Its revision history separates the 2025 additions (USB, I3C, flashless boot, multi-stage activation) from the older recovery protocol. It is a reference for teams writing security and resiliency requirements for server platforms.
CC BY-SA 4.0: share with attribution under the same licence
On this page
Overview
Cloud data-centre servers contain many devices running firmware. Before OCP Secure Firmware Recovery was created, servers had no standardised, open protocol for recovering device firmware from accidental or malicious corruption. The document fills that gap by defining how a device's firmware is recovered over SMBus, I3C and USB. Its guidance rests on the three pillars of platform resiliency in NIST SP 800-193: protection (secure boot, attestation, threat model), detection (the OCP component attestation document) and recovery (this document).
The architecture separates the device being recovered (AC-RoT), the system component that determines device health and initiates recovery (PA-RoT) and the Recovery Agent (RA) that performs it. If a device fails attestation and is functional, a standard firmware update (for example the DMTF PLDM update specification) is used; if the device detects a failure and voluntarily enters recovery, the recovery interface downloads or selects an image; if the device is unresponsive, administrative forced recovery is used, and if that is not enabled the device may have to be returned to the manufacturer. Because forced recovery implicitly trusts the RA, the document notes that the interface could be used for denial of service by repeated resets.
The core of the protocol is the indirect memory interface: component memory spaces (CMS) are mapped to an indirect data window with 4-byte alignment. A recovery image is pushed with the indirect memory protocol to the code CMS, or a local image is selected, and an activation command then restarts the device into its immutable trust anchor. Status registers report recovery pending, awaiting image, booting, successful and failed states. Version 1.1 is dated 19 December 2025 and adds USB support and clarifies maximum response time and heartbeat period definitions; version 1.1-rc8 of 22 May 2025 added flashless boot mode, multi-stage activation, I3C support and FIFO support.
In scope, the document defines firmware recovery behaviour of server components and platform management controllers; it does not address facility or cooling topics. The revision history runs from the 0.9 draft (13 April 2021) through 1.0 final (14 September 2022) and 1.01 (maximum INDIRECT_DATA return of 252 bytes). The document is licensed CC BY-SA 4.0 and is designed to be read together with the OCP Hardware Secure Boot and OCP Attestation documents.
Key points
- Version 1.1 is dated 19 December 2025 and adds USB support; it clarifies the heartbeat period and maximum response time definitions.
- Version 1.1-rc8 (22 May 2025) added flashless boot, multi-stage activation, I3C support and FIFO support.
- The protocol defines three physical interfaces: SMBus, I3C and USB.
- Three pillars of resiliency: protection (secure boot, attestation), detection (the OCP attestation document) and recovery (this document), based on NIST SP 800-193.
- Roles: the device being recovered (AC-RoT), the PA-RoT that determines health on the system side and the Recovery Agent (RA) that performs recovery.
- Forced recovery should be enabled by default (it can be administratively disabled); because it implicitly trusts the RA, repeated resets could cause denial of service.
- The recovery image is pushed with the indirect memory protocol and activation restarts the device into its immutable trust anchor; the device reports recovery status in a status register at each stage.
- Offsets within a component memory space are 4-byte aligned; in version 1.01 the maximum INDIRECT_DATA return is 252 bytes.
- A device that cannot keep critical data through recovery must re-establish it or be returned to the manufacturer.
Using it in design
- In platform and server procurement specifications, require NIST SP 800-193-aligned recovery capability and the OCP Secure Firmware Recovery protocol (SMBus, I3C or USB) for every programmable device.
- In management-network and board design, plan the physical access path and isolation of the recovery interface (SMBus topology, I3C or USB) from the PA-RoT to each device.
- In the security policy, define the balance between forced recovery staying enabled by default and managing the denial-of-service risk; write authorisation and permission steps into operating procedures.
- Add a decision tree to the commissioning and maintenance procedure for a device that fails attestation: update, voluntary recovery, forced recovery and return to manufacturer.
- Ask the supplier in writing whether the device keeps critical data through recovery and whether it supports flashless boot.
Who should read it
Hardware engineers designing server and platform security, BMC and firmware developers, and reliability and procurement teams.
Document contents
- Purpose, audience, syntax and conventions
- Introduction (relationship to other OCP security documents, SP 800-193 alignment, detection and remediation, recovery requirements, authorization, reasons, use cases)
- Roles (RA and PA-RoT recovery role, AC-RoT recovery role, recovery image)
- Recovery flow (device reset, forced recovery, flashless boot, image push, selection, activation, authentication, normal operation)
- Interfaces (capability/discovery, indirect memory interface, SMBus, I3C, USB)
- Error handling and command summary
Read the document
ocp-security-recovery-1-1-r4.pdf
CC BY-SA 4.0: share with attribution under the same licence
The document is provided unaltered because its licence permits redistribution.
Publication details
- Authors
- Eric Spada (editor); Varun Sampath (editor); Mariusz Oriol (editor)
- Publisher
- Open Compute Project
- Year
- 2025
- Document number
- Secure Firmware Recovery, Version 1.1
- Document language
- English
- Source type
- Industry body
- Access
- Open licence (downloadable)
- Licence
- CC BY-SA 4.0: share with attribution under the same licence
- Licence evidence
- www.opencompute.org
Original licence note
Creative Commons Attribution-ShareAlike 4.0 International; licence verified from the licence statement in the document itself. Attribution to the authors and publisher is kept; adaptations must keep the same licence.
Citation
Eric Spada (editor); Varun Sampath (editor); Mariusz Oriol (editor) (2025). Secure Firmware Recovery, Version 1.1. Open Compute Project. Secure Firmware Recovery, Version 1.1. https://www.opencompute.org/documents/ocp-recovery-document-1p1-final-pdf/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.