Technical guideFree to read2020

Common Security Threats v1.0 (Open Compute Project)

Original title Common Security Threats v1.0

Open Compute Project · Yigal Edery (editor)

A November 2020 OCP Security workgroup document that treats firmware as the main asset, splits hardware and firmware threats into logical and physical-access attacks, and maps each to secure boot, secure update, attestation and secure recovery.

On this page

Overview

The document builds a common understanding of the hardware and firmware threat scope and maps threats to OCP Security standards (editor Yigal Edery; first release 15 November 2020). It is not a requirements document; it is a mapping for system and component designers, SIEM developers and cloud service providers. The main protected asset is system firmware, and threats are deliberately kept high level.

Threats fall into four groups: in-scope, covered by explicit assumptions, and out of scope. In-scope logical-access threats include execution of unauthorised firmware, authorised firmware with known defects, compromised signing keys, compromised verification keys, misconfiguration, compromised updates, unpatched vulnerabilities, insecure development environment, compromise of the RoT itself and unauthorised resets. Physical-access threats include port attacks, firmware modification over SPI, corruption of both active and backup regions, RoT chip tampering and spoofed systems.

Mitigations rest on four technologies: secure boot (signature and hash validation), secure update (signature checks during update, roll-back prevention), attestation (verifying device measurements before admitting them to the platform) and secure recovery (fallback to a backup or immutable recovery image not on the same flash). A unique unclonable identity per device supports known inventory and rejecting unrecognised devices.

Explicit assumptions are physical security (limited physical access to the target platform) and a secure manufacturing facility; end-to-end supply chain, run-time attacks, secret leakage with unlimited physical access, hardware bugs and bus attacks are out of scope. The document dates from 2020 and reflects v1.0 scope.

Key points

  1. v1.0, first released 15 November 2020; not a requirements document but a map from threats to OCP security specifications.
  2. The main protected asset is firmware; threats apply at system and component level (management, storage subsystems, adapters) together.
  3. Logical-access in-scope threats include unauthorised firmware, old signed versions with known defects, compromised signing and verification keys, and unauthorised resets that avoid re-attestation.
  4. Physical-access in-scope threats: USB or PCIe port attacks, firmware modification over SPI, corrupting both active and backup regions, RoT chip tampering and spoofed systems.
  5. Four core mitigations: secure boot, secure update (including roll-back prevention), attestation and secure recovery.
  6. Devices must re-attest after every reset or firmware update.
  7. Explicit assumptions: limited physical access to the target platform and secure manufacturing; permissive policies that admit devices that cannot attest should be avoided.
  8. Out of scope: end-to-end supply chain, run-time attacks, secret leakage via unlimited physical access, hardware bugs, reset-attack resilience and bus attacks.

Using it in design

  • Add secure boot, signed firmware updates, roll-back prevention and attestation support as mandatory requirements in server and network equipment specifications.
  • Evaluate firmware update servers and signing key management in supplier selection and ask about key revocation support.
  • Design physical security (rack and hall access) as the explicit assumption of the hardware threat model and make it auditable.
  • Write disabling of unused USB and other interfaces into the hardware configuration standard.
  • Base device inventory on unique identity and apply an admission policy that rejects unrecognised devices.

Who should read it

Server and component designers, cloud and data centre security architects, SIEM developers and hardware procurement teams.

Document contents

  1. Purpose and audience
  2. Threats landscape
  3. In-scope threats: attackers with logical access
  4. In-scope threats: attackers with physical access
  5. Explicit assumptions
  6. Out-of-scope threats
  7. Referenced OCP specs
  8. Appendix A: OCP Badge threats checklist

Publication details

Authors
Yigal Edery (editor)
Publisher
Open Compute Project
Year
2020
Document number
Common Security Threats v1.0
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public document inspected; no document-specific redistribution license established.

Citation

Yigal Edery (editor) (2020). Common Security Threats v1.0. Open Compute Project. Common Security Threats v1.0. https://www.opencompute.org/documents/common-security-threats-notes-1-pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.