Technical guidePDF2020

Attestation of System Components v1.0

Open Compute Project · Elaine Palmer (editor)

An OCP specification defining requirements and recommendations for establishing trust in server components through device identity and measured evidence. It covers the platform discovering which devices are present, collecting signed measurements, verifying certificate chains and deciding whether to accept a device.

CC BY-SA 4.0: share with attribution under the same licence

On this page

Overview

The document notes that cloud data-centre servers are filled with subsystems, peripherals, accelerators and firmware from many global suppliers and are typically configured on demand. Until this document, servers had no standardised, open, automated mechanism to establish and verify trust in those products dynamically. Questions such as whether a network adapter still has its manufacturer's initial firmware, whether the latest security patch is on a memory controller's firmware, or which country's certified cryptographic algorithms a storage unit implements cannot be settled by procurement agreements alone. The document is dated 4 November 2020 and is the initial release.

In the design, a platform (a server, BMC or a trusted external service acting in that role) communicates with attester devices. The platform follows five steps: determine which devices are present, collect measurements (such as firmware version and cryptographic functions) from each, verify the device's certificates and the chain to a trusted root, verify the digital signature over the measurements, and accept the device or choose a remedial action. The attester device must contain a tamper-protected immutable hardware root of trust, be provisioned in a secure facility with a unique identity, firmware and keys, implement secure boot that runs only signed and verified firmware, and answer platform requests with signed measurements.

The detailed sections cover keys, seeds and device identifiers, certificate chains, provisioning-facility requirements, device ownership transfer, the discovery and interrogation protocol, authentication, attestation and enrollment, SPDM standards support, measurement collection and storage, and policies. The device identity key is thought of as a trustworthy serial number; each attester is recommended to generate its own identity key pair because injecting the private key opens attack surface. Cryptographic algorithms and random bit generators must be validated, and random bits and keys must come from specified sources. Devices that use SPDM must support at least SPDM version 1.0.

Measurements must include everything that affects the security of the device (executable code, headers, security state and configuration data) but exclude information that makes them brittle, such as frequently updated content. Configuration data that could compromise security, such as fuses or straps enabling JTAG, must be discoverable or make the measurements distinguishable from production measurements. On device reset, the measurement registers must be cleared and a reset-event measurement extended. The document notes that ownership may pass from the initial owner through interim owners to the final user, and that attestation may be performed at any time during the platform's lifecycle.

Key points

  1. Initial release dated 4 November 2020; the document is part of a larger OCP Security Project specification.
  2. The platform's five steps: determine devices, collect measurements, verify certificate chain, verify measurement signature, accept the device or choose remedial action.
  3. Attester device: tamper-protected immutable hardware root of trust, unique identity and key provisioning in a secure facility, secure boot and signed-measurement responses.
  4. The device identity key (DevIK) is a trustworthy serial number; the device is recommended to generate its own key pair because private-key injection opens attack surface.
  5. Cryptographic algorithms and random bit generators must be validated; keys and random bits must come from specified sources.
  6. Devices supporting SPDM must support at least SPDM 1.0; example profiles use SHA-384 and ECDSA NIST P-384.
  7. Measurements must cover everything that affects security and exclude frequently changing data that makes them brittle.
  8. Security-affecting configuration data (for example fuses or straps that enable JTAG) must be discoverable or make measurements distinguishable from production.
  9. On device reset, measurement registers are cleared and a reset-event measurement is extended.

Using it in design

  • In server and subsystem procurement specifications, write requirements for a hardware root of trust, unique identity, signed firmware and a signed-measurement response (SPDM supported) for every device.
  • In BMC and platform design, define the device discovery, measurement collection and certificate-chain verification flow, and the accept or remedial-action policy.
  • Add to the procedure how device ownership transfer (initial owner, interim owners and final operator) and the identity certificate chain are renewed at commissioning.
  • Ask about provisioning-facility requirements (secure environment, operations and equipment) in the supply-chain assurance process; keep in mind that contracts alone cannot assure security.
  • In SIEM integration, define attestation results and device reset events as monitoring points.

Who should read it

System and component designers, SIEM developers, and security and procurement teams at cloud service providers.

Document contents

  1. Purpose, audience, syntax and conventions
  2. Introduction (platforms, attesters and verifiers; interactions; supply chain assurance)
  3. Keys, seeds and device identifiers (keys, entropy and random bits requirements)
  4. Certificate chains and credentials
  5. Protocols (participants, provisioning facility, device ownership provisioning, discovery and interrogation, authentication, attestation and enrollment, SPDM support)
  6. Measurement collection and storage
  7. Policies
  8. Glossary, relevant standards and Appendix A: Summary of requirements and recommendations

Read the document

ocp-security-attestation-r4.pdf

PDF · 1.5 MB · English

CC BY-SA 4.0: share with attribution under the same licence

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
Elaine Palmer (editor)
Publisher
Open Compute Project
Year
2020
Document number
Attestation of System Components v1.0
Document language
English
Source type
Industry body
Access
Open licence (downloadable)
Licence
CC BY-SA 4.0: share with attribution under the same licence
Licence evidence
www.opencompute.org
Original licence note

Creative Commons Attribution-ShareAlike 4.0 International; licence verified from the licence statement in the document itself. Attribution to the authors and publisher is kept; adaptations must keep the same licence.

Citation

Elaine Palmer (editor) (2020). Attestation of System Components v1.0. Open Compute Project. Attestation of System Components v1.0. https://www.opencompute.org/documents/attestation-v1-0-20201104-pdf/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.