Technical guideFree to readYear not stated

Effective, High Performance HVAC Solutions from Carrier, Designed for the Data Center (Europe brochure): Fan Wall W175 and W230

Original title Data center solutions: Fanwall W175 / W230

Carrier

Carrier Europe's data centre brochure: W175 (175 kW, 60,000 m³/h) and W230 (230 kW, 75,000 m³/h) fan walls, AquaSnap and AquaForce chillers, heat recovery and free cooling.

On this page

Overview

The brochure sets out Carrier's response to data centre challenges under decarbonisation, heat recovery, free cooling and building management. For heat recovery it features high-temperature heat pumps, and for free cooling a control system that engages as soon as outdoor air temperature drops below the water network return temperature. Products are listed as fan walls, air handlers, liquid chillers, dry coolers, terminal units and CRAH.

The fan wall section presents a horizontal-airflow, EC-motor integrated cooling solution in a high-tech corridor, with up to 80,000 m³/h per unit. Two models are given: W175 at 175 kW, 60,000 m³/h, 2,700 x 2,000 x 3,100 mm, and W230 at 230 kW, 75,000 m³/h, 3,200 x 2,000 x 3,100 mm, at 35°C return air and 20/30°C chilled water. Options include energy valves with thermal metering, motorised dampers, electrical metering, THDI < 5% harmonic treatment, ATS and ultracapacitor.

Supporting products: AquaSnap 30RBP scroll chiller (225-1,197 kW, R-32, -20 to +50°C), AquaForce 30XF variable-speed screw chiller (R-1234ze, 20-100% capacity, 15% minimum water flow, return to full capacity in under 120 s), AquaForce PUREtec 61XWH-ZE high-temperature heat pump (up to 85°C, up to 1,570 kW), AquaEdge 19DV centrifugal chiller (1,050-3,800 kW, IPLV.IP 12.3), CRAH (5-400 kW) and 100-1,500 kW dry coolers. Some data is preliminary and flagged as available in Q3 2024.

Key points

  1. Fan wall W175: 175 kW, 60,000 m³/h, 2,700 x 2,000 x 3,100 mm; W230: 230 kW, 75,000 m³/h, 3,200 x 2,000 x 3,100 mm (return air 35°C, water 20/30°C).
  2. Fan walls reach up to 80,000 m³/h per unit with EC motors and horizontal airflow; options include ATS, ultracapacitor and THDI < 5%.
  3. CRAH W40-W400: 45-438 kW, maximum airflow 13,300-120,000 m³/h (return 35°C, water 15/20°C).
  4. AquaSnap 30RBP: 225-1,197 kW, EER 3.06-3.7, 100% free cooling at ambient 4-6°C (35°C outdoor, 20/30°C), R-32.
  5. AquaForce 30XF: 381-2,039 kW, EER 3.59-3.90 (30/20°C, 30% EG, free cooling), R-1234ze (GWP 7), THDI < 5%, full capacity in under 120 s.
  6. 61XWH-ZE heat pump: 300-1,570 kW, water up to 85°C, connection to urban networks.
  7. AquaEdge 19DV: 1,050-3,800 kW, IPLV.IP 12.3, R-1233zd(E) (GWP < 1), sample models show COP of 6.9-7.2.
  8. Dry coolers 100-1,500 kW; air handling units 1,000-40,000 m³/h.

Using it in design

  • Compare the fan wall capacity at 35°C return and 20/30°C water against your own conditions; the brochure marks the fan wall as 'offer under request' with 39CZ range adaptations.
  • Calculate free cooling from hours when outdoor temperature falls below the water return temperature; a 20/30°C high-temperature water design increases those hours.
  • In chiller selection, check rapid capacity recovery (120-150 s), minimum water flow and harmonics (THDI < 5%) against UPS and generator interaction.
  • If waste heat can be used, match the heat pump producing up to 85°C to urban or industrial consumers.
  • For values flagged preliminary, confirm the final technical datasheet and availability date.

Who should read it

Mechanical designers selecting data centre thermal plant and decision makers screening the Carrier range.

Document contents

  1. Carrier's response to data centre challenges
  2. Efficient, high-performing Carrier HVAC solutions
  3. Air-to-water ranges
  4. Water-to-water ranges
  5. Computer room air handlers and fan walls
  6. Air handling units and dry coolers
  7. Service

Publication details

Authors
Carrier
Publisher
Carrier
Year
Year not stated
Document number
NA2234B
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Carrier Data center solutions: Fanwall W175 / W230. Carrier. NA2234B. https://brandportal.carrier.com/m/7118d3d186fa88bc/original/NA2234B_brochure_datacenter_europe_EN_bd.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.