Technical guideFree to read2025

Cross-Sector Cybersecurity Performance Goals, Version 2.0 (CPG 2.0)

Cybersecurity and Infrastructure Security Agency (CISA)

CISA's December 2025 CPG 2.0 revision aligns baseline cybersecurity goals for critical infrastructure to the six NIST CSF 2.0 functions, including GOVERN, and merges IT and OT goals into one set.

On this page

Overview

CISA's December 2025 revision organises baseline cybersecurity goals for critical infrastructure under the six NIST CSF 2.0 functions: GOVERN, IDENTIFY, PROTECT, DETECT, RESPOND and RECOVER. The OT-only goals of CPG 1.0.1 were folded into universal goals so that one set covers IT, IoT and OT.

Each goal lists the risk addressed, recommended action, OT-specific notes, CSF references and relative cost, impact and ease-of-implementation ratings. Goals include a maintained asset inventory (2.A), changing default passwords including on existing OT systems (3.A), multifactor authentication (3.F) and logical and physical network segmentation including physically segmented OT enclaves (3.I). It works as a practical, attestable checklist for data centre IT and facility OT security.

Key points

  1. Goals are organised under GOVERN, IDENTIFY, PROTECT, DETECT, RESPOND and RECOVER, mirroring NIST CSF 2.0.
  2. The OT-only goals of CPG 1.0.1 were folded into universal goals; one set covers IT, IoT and OT.
  3. Goal 2.A: a maintained asset inventory, with OT-specific inventory guidance.
  4. Goal 3.A: change default passwords including on existing OT systems, with compensating controls where passwords are hard-coded.
  5. Goals 3.F (multifactor authentication) and 3.I (logical and physical network segmentation, including physically segmented OT enclaves where applicable) are included.
  6. Each goal lists cost, impact and ease-of-implementation ratings plus NIST CSF 2.0 references.

Using it in design

  • Keep data centre IT and facility OT assets in one inventory and mark OT devices separately.
  • Make changed default passwords an acceptance criterion at commissioning.
  • Design logical and, where needed, physical segmentation and multifactor authentication for the OT network.
  • Prioritise goals by cost, impact and difficulty ratings and tie them to the security roadmap.

Who should read it

Data centre IT and facility OT security owners, compliance managers and design teams.

Related standards

  • NIST CSF 2.0
  • NIST SP 800-82 Rev. 3
  • IEC 62443

Publication details

Authors
Cybersecurity and Infrastructure Security Agency (CISA)
Publisher
Cybersecurity and Infrastructure Security Agency (CISA)
Year
2025
Document number
CPG 2.0
Document language
English
Source type
Expert / community
Access
Free to read
Licence
U.S. public domain: U.S. Government work; free to reuse
Original licence note

U.S. federal government work; document marked TLP:CLEAR (distribution not limited). Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Cybersecurity and Infrastructure Security Agency (CISA) (2025). Cross-Sector Cybersecurity Performance Goals, Version 2.0 (CPG 2.0). Cybersecurity and Infrastructure Security Agency (CISA). CPG 2.0. https://www.cisa.gov/sites/default/files/2025-12/CPG_Report_2.0_508c.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.