Liquid cooling

Collection: Direct-to-chip, immersion, CDUs and facility water interfaces.

Sources
320
Downloadable PDFs
58
Years
2011–2026

All sources

73–96 / 320

Liquid Cooling Integration and Logistics White Paper, Revision 1.0

Open Compute Project Foundation, 2021, Guide or technical publication

An OCP Advanced Cooling Solutions white paper that describes the full lifecycle of cold-plate liquid-cooled servers and racks, from manufacturing to decommissioning, with particular attention to leak…

Guide or technical publication

2021

PDF

Liquid to Liquid CDU Test Methodology and Performance Rating, Revision 1.0

Open Compute Project Foundation, 2024, Guide or technical publication

An OCP white paper by authors from Intel, CoolIT and Meta that gives liquid-to-liquid coolant distribution units (CDUs), which separate the technology cooling system (TCS) from the facility water…

Guide or technical publication

2024

PDF

Material Compatibility in Immersion Cooling, Revision 1.0 (Nov 28, 2022)

Open Compute Project Foundation, 2022, Guide or technical publication

An OCP Advanced Cooling Solutions immersion sub-project document on how dielectric fluids interact with IT and facility materials, with failure mechanisms, a standard fluid-ageing test and acceptance…

Guide or technical publication

2022

PDF

Plate Heat Exchangers Base Specification, Rev 0 Version 1.0

Open Compute Project Foundation, 2025, Guide or technical publication

The vendor-authored OCP base specification for plate heat exchangers used in data centres (effective 22 August 2025). It sets baseline pressure, material, labelling and documentation requirements…

Guide or technical publication

2025

PDF

Reservoir and Pumping Unit (RPU) Specification, Ver 1.0

Open Compute Project Foundation, 2022, Guide or technical publication

A Meta and CoolIT specification for the rack-mounted reservoir and pumping unit, the control and pumping hub of an air-assisted liquid cooling (AALC) system. It standardizes a way to add liquid-coole…

Guide or technical publication

2022

PDF

Unraveling the Efficiency, Performance and Sustainability Trade-Offs: Case Study of Liquid Assisted Air Cooling vs Traditional Air Cooling (OCP EMEA Summit 2025)

Open Compute Project Foundation, 2025, Guide or technical publication

Cloudflare compares a liquid-assisted air-cooled (LAAC) 2U server, where a closed-loop cold plate dumps CPU heat to an in-chassis radiator, with the same server using a conventional heat sink. It is…

Guide or technical publication

2025

Read at publisher (opens in a new tab)

Disrupting data-centre design: liquid cooling in the AI era (Veri Merkezi Tasarımında Ezber Bozan Yaklaşım – Yapay Zeka Çağında Soğutma Stratejisi: Sıvı Soğutma ile Dönüşen Veri Merkezleri)

KPMG Türkiye, 2025, Guide or technical publication

A KPMG Türkiye insight for boards and investors on why liquid cooling is becoming necessary for AI data centres, with costs and the hidden infrastructure requirements.

Guide or technical publication

2025

Read at publisher (opens in a new tab)

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.