Duyar T-1205 Smart Valve: control and measurement features
Original title Smart Valve T-1205: Controls and Measurement Features
Duyar
Duyar's T-1205 Smart Valve is a DN50 and DN65, PN16 valve combining pressure-independent control with ultrasonic flow, temperature, energy and differential-pressure measurement, with Modbus RTU/TCP and MQTT communication.
On this page
Overview
The page presents Duyar's Smart Valve System, catalogue code T-1205. The product is a special valve used in heating, cooling and automation systems to raise energy efficiency and control precision. By controlling the flow of the carrier liquid, it lets the system consume only the energy needed; its pressure-independent control feature makes flow control easier.
The system has intelligent control mechanisms that can adjust fluid flow automatically. Through a web interface, IoT and Modbus communication protocols, users can analyse the data they want and keep full control of the installation network. The manufacturer states it lowers cost in building heating and cooling by optimising energy consumption and raising maintenance and control precision.
System specifications: supply 220 VAC or 24 VDC, cable connection 3 x 1.5 mm², internet connection wired (RJ45) or wireless. Control type Modbus RTU, Modbus TCP, MQTT and cloud. Measurement features: ultrasonic flow, temperature, temperature difference, energy and differential-pressure measurement. Scenario options: position, flow (EPICV), energy, ΔT and ΔP scenarios, instant data tracking and 0-10 V DC or 4-20 mA analogue outputs.
Mechanical specifications: nominal diameter DN50 and DN65, PN 16, working temperature 4 °C to 90 °C (with a +150 °C short-term note). Brass threaded and ductile iron body options exist. The application area is automation systems. The page gives no flow range, Kvs value or accuracy figures.
Key points
- Catalogue code T-1205; brass threaded and ductile iron body options.
- DN50 and DN65; PN16; working temperature 4 to 90 °C.
- Supply 220 VAC / 24 VDC; cable 3 x 1.5 mm².
- Communication: Modbus RTU, Modbus TCP, MQTT, cloud; wired (RJ45) or wireless internet.
- Measurement: ultrasonic flow, temperature, ΔT, energy, differential pressure.
- Scenarios: position, flow (EPICV), energy, ΔT, ΔP; instant data tracking.
- Analogue output: 0-10 V DC or 4-20 mA.
- Pressure-independent control; web interface and IoT access.
Using it in design
- Consider it for combining flow and energy metering in one valve on chilled-water headers and on critical branches such as CRAH, fan wall and RDHx (DN50 or DN65 lines).
- Use the ΔT scenario to build a control strategy that avoids low Delta-T syndrome; share ΔT and ΔP setpoints with the BMS.
- Bring Modbus RTU/TCP or MQTT into the BMS and DCIM integration scope; use the 0-10 V or 4-20 mA analogue outputs for legacy systems.
- Compare the PN16 and 4-90 °C limits with the chilled-water regime and test pressure.
- Because the page has no flow range or Kvs, request the technical document from the manufacturer before sizing.
Who should read it
Mechanical and automation engineers designing chilled-water distribution and branch-level flow control.
Document contents
- Product description
- System specifications
- Measurement features and scenario selection
- Technical specifications (nominal diameter, PN, temperature)
- Applications
Publication details
- Authors
- Duyar
- Publisher
- Duyar
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Public source opened on the access date. No open redistribution licence established; metadata and original short summaries only. Landing-page technical content only; detailed configuration-dependent limits must be checked against selected equipment.
Citation
Duyar Smart Valve T-1205: Controls and Measurement Features. Duyar. https://duyar.com/smart-valve-
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.