Research paperFree to read2024

Immersion cooling technology development status of data center

Science and Technology for Energy Transition (EDP Sciences) · Kun Zhou, Xiaolin Yu et al.

A 2024 review in Science and Technology for Energy Transition comparing single-phase and two-phase immersion cooling; in China data centres use about 4% of electricity and cooling 30-50% of site energy.

On this page

Overview

The review states that data-centre energy consumption keeps rising with IT equipment development. According to the authors, China's data centres account for 4% of society's electricity consumption and cooling systems take 30 to 50% of data-centre energy. With new high-power chips, traditional cooling methods can no longer meet IT cooling requirements.

The paper therefore takes up immersion cooling, which addresses high heat-flux density and cooling energy together. It compares the working principles, development status and application prospects of single-phase and two-phase immersion cooling.

It also discusses waste heat utilisation in immersion-cooled data centres. The article is a compact background reference for readers comparing immersion variants; it offers a general framework rather than detailed design data.

Key points

  1. According to the authors, cooling systems take 30-50% of data-centre energy.
  2. Data centres in China account for about 4% of society's electricity consumption.
  3. Traditional cooling can no longer meet the needs of new high-power chips.
  4. Principles, development status and prospects of single-phase and two-phase immersion are compared.
  5. Waste heat utilisation from immersion systems is discussed.

Using it in design

  • Use the review's principle comparison as a starting frame when pre-selecting between single-phase and two-phase immersion.
  • Use the 30-50% cooling energy share as a reference in the business case.
  • Evaluate immersion fluid temperature level together with the heat consumer for waste heat recovery.
  • Verify design values separately with manufacturer and test data.

Who should read it

Designers new to immersion cooling, decision makers choosing technology and researchers.

Publication details

Authors
Kun Zhou; Xiaolin Yu; Baogang Xie; Hongxi Xie; Wei Fu
Publisher
Science and Technology for Energy Transition (EDP Sciences)
Year
2024
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Publisher-deposited Crossref licence metadata: https://creativecommons.org/licenses/by/4.0 (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Kun Zhou; Xiaolin Yu; Baogang Xie; Hongxi Xie; Wei Fu (2024). Immersion cooling technology development status of data center. Science and Technology for Energy Transition (EDP Sciences). https://doi.org/10.2516/stet/2024022

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.