Immersion cooling technology development status of data center
Science and Technology for Energy Transition (EDP Sciences) · Kun Zhou, Xiaolin Yu et al.
A 2024 review in Science and Technology for Energy Transition comparing single-phase and two-phase immersion cooling; in China data centres use about 4% of electricity and cooling 30-50% of site energy.
On this page
Overview
The review states that data-centre energy consumption keeps rising with IT equipment development. According to the authors, China's data centres account for 4% of society's electricity consumption and cooling systems take 30 to 50% of data-centre energy. With new high-power chips, traditional cooling methods can no longer meet IT cooling requirements.
The paper therefore takes up immersion cooling, which addresses high heat-flux density and cooling energy together. It compares the working principles, development status and application prospects of single-phase and two-phase immersion cooling.
It also discusses waste heat utilisation in immersion-cooled data centres. The article is a compact background reference for readers comparing immersion variants; it offers a general framework rather than detailed design data.
Key points
- According to the authors, cooling systems take 30-50% of data-centre energy.
- Data centres in China account for about 4% of society's electricity consumption.
- Traditional cooling can no longer meet the needs of new high-power chips.
- Principles, development status and prospects of single-phase and two-phase immersion are compared.
- Waste heat utilisation from immersion systems is discussed.
Using it in design
- Use the review's principle comparison as a starting frame when pre-selecting between single-phase and two-phase immersion.
- Use the 30-50% cooling energy share as a reference in the business case.
- Evaluate immersion fluid temperature level together with the heat consumer for waste heat recovery.
- Verify design values separately with manufacturer and test data.
Who should read it
Designers new to immersion cooling, decision makers choosing technology and researchers.
Publication details
- Authors
- Kun Zhou; Xiaolin Yu; Baogang Xie; Hongxi Xie; Wei Fu
- Publisher
- Science and Technology for Energy Transition (EDP Sciences)
- Year
- 2024
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- CC BY 4.0: share with attribution
Original licence note
Publisher-deposited Crossref licence metadata: https://creativecommons.org/licenses/by/4.0 (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.
Citation
Kun Zhou; Xiaolin Yu; Baogang Xie; Hongxi Xie; Wei Fu (2024). Immersion cooling technology development status of data center. Science and Technology for Energy Transition (EDP Sciences). https://doi.org/10.2516/stet/2024022
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.