An EEC blog post of 25 April 2017 summarising data centre physical security as fire detection (aspirating smoke detection), mantrap and biometric access control, CCTV analytics and unified security management on one map.

On this page

Overview

The post groups the electronic security systems of a data centre into three: fire detection and alarm, access control, and CCTV and video control. The author is Engin Ozer of the integrator EEC. It says physical security of data centres can be provided with these systems and briefly describes the data centre application of each.

For fire detection, highly sensitive aspirating smoke detection is called well suited to data centres: it is said to give sensitive and stable detection in clean, high, narrow or inaccessible spaces where conventional smoke detection is difficult, and EEC states that almost all its recent data centre systems use it. For access control it describes recording all entries and exits, a two-door mantrap for high security, authorisation by palm, iris or face recognition, and RFID tags recording which cabinet a person worked at and for how long.

The CCTV section lists intelligent camera analytics for density analysis, time spent per cabinet, routes used and density statistics, and detecting a person who has fainted. The security management section describes placing detectors, readers, sensors and cameras on one map for one-click monitoring and control, with building and data centre management systems exchanging data. The text is a short promotional post with no measured data or standard references and dates from 2017.

Key points

  1. Data centre electronic security has three systems: fire detection and alarm, access control, and CCTV and video control.
  2. Highly sensitive aspirating smoke detection is recommended where conventional detection falls short in clean, high, narrow or inaccessible spaces.
  3. The author's firm used aspirating detection in almost all of its recent data centre fire detection systems.
  4. Access control records all entries and exits; a two-door mantrap is recommended for high security.
  5. Authorisation can use palm, iris or face recognition; RFID tags can record which cabinet a person worked at and for how long.
  6. Camera analytics give time per cabinet, routes used and density by time slot; a person who has fainted can be detected.
  7. Management software puts all detectors, readers, sensors and cameras on one map for monitoring and control; building and data centre systems can exchange data.

Using it in design

  • Plan data hall fire detection with aspirating smoke detection and place sampling points by airflow.
  • Design a two-door mantrap and biometric verification at the data centre entrance; add RFID location logging where cabinet-level access records are needed.
  • Define CCTV coverage by entrances, corridors and cabinet rows and write analytics requirements (density, dwell time, fall detection) into the specification.
  • Unify fire, access control and video in one map-based management software and define data exchange with the building management system.

Who should read it

Electrical engineers and facility managers designing data centre electronic security and fire detection systems.

Document contents

  1. Fire detection in data centers
  2. Access control solutions in data centers
  3. CCTV and video control systems in data centers
  4. Security management in data centers

Publication details

Authors
Engin Özer
Publisher
EEC Entegre Bina Kontrol Sistemleri
Year
2017
Document language
Turkish
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public source inspected. No document-specific redistribution permission established; metadata and original brief summaries only. Local downloads are research evidence, not a redistribution package.

Citation

Engin Özer (2017). Veri Merkezi Güvenlik Çözümleri. EEC Entegre Bina Kontrol Sistemleri. https://www.eec.com.tr/blog/veri-merkezi-guvenlik-cozumleri

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.