Generative AI impact assessment through a life cycle analysis of multiple data center typologies
Applied Energy (Elsevier BV) · Alexandre d'Orgeval, Stuart Sheehan et al.
A 2026 Applied Energy paper compares the training and inference footprint of generative AI across data-centre architectures from edge to AI-dedicated facilities in a 20-year life cycle simulation.
On this page
Overview
The study applies life cycle assessment (LCA) to both the training and inference phases of generative AI systems. It notes that earlier work focused mainly on server-level assessments or energy-consumption analyses, whereas this work covers the full lifecycle of data centres and complete architectural configurations.
Two simulation use cases are presented. The first compares architectures over 20 years on total emissions, emissions per year and emissions per installed IT MW, with emissions per FLOPS added for GPU-based architectures. The second compares the footprint of GPT-4o, LLaMA 3.1 405B and DeepSeek V3 to quantify the trade-off between benchmark performance and environmental impact.
Highlighted findings: impacts extend well beyond servers; high-density, liquid-cooled designs give the lowest environmental cost per eFLOP; model choice significantly alters the footprint; and geographic location and grid carbon intensity influence the result.
Key points
- Full-architecture LCA shows generative AI impacts extend far beyond servers alone.
- A 20-year simulation compares total emissions, emissions per year and emissions per installed IT MW.
- Emissions per FLOPS are evaluated for GPU-based architectures.
- High-density, liquid-cooled designs yield the lowest environmental cost per eFLOP.
- Model choice among GPT-4o, LLaMA 3.1 405B and DeepSeek V3 significantly alters the footprint.
- Geographic location and grid carbon intensity influence the impacts.
Using it in design
- When comparing AI facility options, assess emissions per installed IT MW over the whole lifecycle, not only operating energy.
- Compare a high-density liquid-cooled option with an air-cooled alternative using emissions per eFLOP.
- Use grid carbon intensity as a core input of the emissions model in site selection.
Who should read it
Planners comparing AI data-centre options, sustainability analysts and researchers.
Related standards
- ISO 14040/14044
Publication details
- Authors
- Alexandre d'Orgeval; Stuart Sheehan; Quentin Avenas; Edi Assoumou; Valentina Sessa
- Publisher
- Applied Energy (Elsevier BV)
- Year
- 2026
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- CC BY 4.0: share with attribution
Original licence note
Publisher-deposited Crossref licence metadata: http://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.
Citation
Alexandre d'Orgeval; Stuart Sheehan; Quentin Avenas; Edi Assoumou; Valentina Sessa (2026). Generative AI impact assessment through a life cycle analysis of multiple data center typologies. Applied Energy (Elsevier BV). https://doi.org/10.1016/j.apenergy.2025.127288
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.