Eurovent certified dry cooler directory
Eurovent Certita Certification
Eurovent Certita Certification's open directory lists certified dry cooler models with energy class, cooling capacity, 10 m sound pressure and fluid-side pressure drop at four fan speeds (very low to very high).
On this page
Overview
The Eurovent Certita Certification certified product directory is an open register for searching, comparing and verifying independently certified HVACR products and performance data. The dry cooler product type in the heat exchangers programme can be searched by brand, range, model name or certificate number, and results can be exported as csv.
The search criteria cover energy class, energy efficiency ratio (kW/W) and, for each fan speed, cooling capacity, sound pressure level at 10 m and fluid-side pressure drop. Fan speed steps are very low, low, medium, high and very high, each with its own standard condition definition.
Individual model pages hold the SC15 capacity, fan power, airflow, fluid and sound values together. The register does not validate a project duty point; capacity is the value measured at specific certification conditions and must be recalculated for project entering temperature, fluid mixture and altitude.
Key points
- The directory makes independently certified dry cooler model data searchable by brand, range and model name.
- Search filters are energy class, energy efficiency ratio (kW/W), cooling capacity, 10 m sound pressure and fluid-side pressure drop.
- Fan speed steps: very low, low, medium, high, very high; each has a standard condition definition.
- An individual model page holds SC15 capacity, fan power, airflow, fluid and sound values together.
- Results can be exported as csv.
- The record does not verify a project duty point; certified conditions differ from project conditions.
Using it in design
- Start dry cooler selection from certified capacity; compare the capacity in the maker's catalogue with the certified value in the directory.
- Use capacity and sound pressure at several fan speeds to set the fan step for the night or part-load operating point.
- Recalculate capacity from the certified standard condition to the project condition (ambient, entering water, glycol ratio).
- Use energy class and kW/W in the energy comparison, and check fan power and airflow together with noise limits.
Who should read it
Mechanical engineers and purchasing teams comparing dry coolers and requiring certified data.
Publication details
- Authors
- Eurovent Certita Certification
- Publisher
- Eurovent Certita Certification
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Eurovent Certita Certification Eurovent certified dry cooler directory. Eurovent Certita Certification. https://www.eurovent-certification.com/en/advancedsearch/result?program=HE&product_type=HE%2FDCOOL%2FDCOOL
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.