FEMA E-74: Reducing the Risks of Nonstructural Earthquake Damage, A Practical Guide

Original title FEMA E-74: Reducing the Risks of Nonstructural Earthquake Damage – A Practical Guide

Federal Emergency Management Agency (FEMA)

FEMA E-74 is a Federal Emergency Management Agency practical guide to reducing nonstructural earthquake damage risk, covering architectural, mechanical, electrical and plumbing systems, furniture and equipment.

On this page

Overview

FEMA E-74 is the US Federal Emergency Management Agency's guide to reducing earthquake risk to nonstructural components. The publisher's earthquake training page links the guide's PDF and the associated training. The page defines the scope as architectural, mechanical, electrical and plumbing systems plus furniture and equipment, and describes equipment and building services as nonstructural components.

For data-centre design, the subject is keeping server racks, power distribution, cooling equipment, piping and cable routes in place and working through an earthquake. Because these components can be damaged independently of the structural system, service can be interrupted even when the building structure survives.

Key points

  1. Publisher: US Federal Emergency Management Agency (FEMA), document number FEMA E-74.
  2. Scope: architectural, mechanical, electrical and plumbing systems, furniture and equipment.
  3. Equipment and building services are defined as nonstructural components.
  4. The official training page links the E-74 practical guide PDF.
  5. The guide is a practical reference for reducing nonstructural damage risk.

Using it in design

  • List racks, UPS, switchgear, cooling units and cable trays in the data hall as nonstructural components needing seismic anchorage and bracing.
  • Check supports and flexible connections for piping, ducts and electrical services against these component classes.
  • Include all components that could affect continuity of function, architectural elements and furniture among them, in the seismic risk assessment.
  • Cite the guide as a design reference together with the region's applicable seismic code.

Who should read it

Engineers and facility managers designing equipment layout and anchorage for data centres in seismic regions.

Publication details

Authors
Federal Emergency Management Agency (FEMA)
Publisher
Federal Emergency Management Agency (FEMA)
Year
Year not stated
Document number
FEMA E-74
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

FEMA landing opened with TinyFish; linked PDF fetch returned 403. The page shows no document-specific redistribution licence. Despite federal publication provenance, third-party permissions in this guide were not inspected; conservative link-only metadata. Edition year is omitted because the PDF was not successfully opened.

Citation

Federal Emergency Management Agency (FEMA) FEMA E-74: Reducing the Risks of Nonstructural Earthquake Damage – A Practical Guide. Federal Emergency Management Agency (FEMA). FEMA E-74. https://www.fema.gov/emergency-managers/risk-management/earthquake/training/fema-e-74

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.