Enhancing Data Center Performance with Immersion Cooling and Precision-Engineered Fluids

GRC / ENEOS

A GRC and ENEOS white paper explaining that single-phase immersion cooling fluids are not interchangeable and how fluid selection affects performance, health, safety and sustainability.

On this page

Overview

This white paper, published by GRC (Green Revolution Cooling) with ENEOS, is a primer meant to simplify single-phase immersion cooling fluid selection. It argues that immersion cooling has helped enable the rapid rise of high-performance computing, but that not all single-phase fluids are the same, and that knowing the difference can have a large effect on data center performance.

The paper covers why the right fluid is key to performance, the health, safety and sustainability considerations, the factors in GRC's ElectroSafe fluid partner testing programme, and the testing regimens every operator should demand. A closing section describes how GRC and ENEOS reduce the complexity of fluid selection.

It is offered as a form-gated download aimed at data center operators; the page gives no numeric values.

Key points

  1. Single-phase immersion cooling fluids differ from one another and the choice affects data center performance.
  2. Health, safety and sustainability are treated as part of fluid selection.
  3. The elements of GRC's ElectroSafe fluid partner testing programme are explained.
  4. Testing regimens that operators should require from the fluid supplier are listed.
  5. The publishers are GRC and the fluid maker ENEOS.

Using it in design

  • Select the immersion fluid on material compatibility, health, safety and sustainability as well as thermal properties.
  • Ask the fluid supplier for independent test reports and a test regimen, and add an acceptance-test clause to the specification.
  • Confirm compatibility of IT hardware (gaskets, cables, thermal paste) with the fluid with the hardware manufacturer.
  • Write a fluid monitoring and sampling plan covering the fluid's service life into the operating procedure.

Who should read it

Data center designers, operators and procurement teams selecting an immersion cooling fluid.

Publication details

Authors
GRC / ENEOS
Publisher
GRC / ENEOS
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official landing page and linked PDF opened with TinyFish on 2026-11-16; the page offers a free download but neither opened source grants an open reuse licence. Treat as vendor copyright, citation only. The file path suggests 2023, but no publication date was verified in the document, so year is omitted. PDF source: https://grcooling.com/wp-content/uploads/2023/11/grc_eneos_white_paper_enhancing_data_center_performance.pdf

Citation

GRC / ENEOS Enhancing Data Center Performance with Immersion Cooling and Precision-Engineered Fluids. GRC / ENEOS. https://www.grcooling.com/learning-center/immersion-cooling-and-precision-engineered-fluids-eneos/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.