Technical guideFree to readYear not stated

HCS Installation Information (Structured Cabling)

Original title HCS Kurulum Bilgileri

HES Cabling Systems

A Turkish structured cabling installation guide from HES Cabling Systems covering cable pulling, bending, cable ties and link length choices; an undated manufacturer installation page.

On this page

Overview

The HCS (HES Cabling Systems) installation information page is a manufacturer guide that explains in Turkish how to install structured cabling systems in the field. It dwells on cable pulling, bending, cable ties and link length choices. The document is undated and published as a manufacturer information page.

The basic installation section recommends keeping cable ties soft and loose, stripping only as much jacket as needed for termination, and using suitable installation and test tools. HCS separates its general link length table from the Cat 6A/Class EA table and states that it lists its own limits. These tables should be read as values for the manufacturer's own products, not as universal field acceptance for all cables.

Key points

  1. Cable ties should be kept soft and loose.
  2. Only as much jacket as needed should be stripped for termination.
  3. Suitable installation and test tools should be used.
  4. A general link length table and a Cat 6A/Class EA table are given separately.
  5. The tables show the manufacturer's own limits and do not imply automatic suitability for all cables.

Using it in design

  • Add field rules for cable tie tightness and jacket stripping length to the installation specification.
  • Verify link length limits against the chosen cable's datasheet values and applicable standards.
  • Apply separate length and test criteria to Cat 6A/Class EA channels.
  • Use the manufacturer guide as a field practice note, not in place of a standard.

Who should read it

Field technicians installing structured cabling, cabling designers and projects seeking a Turkish installation guide.

Publication details

Authors
HES Cabling Systems
Publisher
HES Cabling Systems
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

HES Cabling Systems HCS Kurulum Bilgileri. HES Cabling Systems. https://hescs.com/tr/statik.php?pg=kur

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.