Powering data centers sustainably in an AI world: Artificial Intelligence - Friend or Foe of Sustainable Data Centers?
Hitachi Energy
A Hitachi Energy technical brief addressing how AI raises data-centre electricity demand while AI-assisted facility management can deliver efficiency gains.
On this page
Overview
The Hitachi Energy technical brief states that data centres are getting bigger, denser and more power-hungry, and that AI is accelerating this process. It also argues that AI could be a powerful tool for improving data-centre energy efficiency.
The brief explores the factors driving rapid growth in data-centre energy demand, steps being taken to mitigate fast-growing consumption trends, and the role AI could play in the future evolution of both data-centre management and the clean energy transition. The document is a technical brief downloaded through a form; its public description covers both higher AI computing demand and AI applications for energy efficiency.
Key points
- Data centres are getting bigger, denser and more power-hungry; AI accelerates the process.
- AI can also be used to improve data-centre energy efficiency.
- The brief covers the factors driving growth in energy demand.
- The brief covers steps taken to mitigate fast-growing consumption.
- It considers AI's role in future data-centre management and the clean energy transition.
Using it in design
- Plan power and cooling capacity for AI loads against high-density and fast-growth scenarios.
- Prepare telemetry (power, temperature, cooling) in the design for AI-assisted monitoring and optimisation of facility management.
- Evaluate measures that reduce demand growth, such as efficient power and cooling architecture, at concept stage.
- Include the effect of AI-driven load growth on the grid connection and clean energy supply plan in the capacity study.
Who should read it
Designers and energy managers planning power infrastructure for AI-heavy data centres.
Publication details
- Authors
- Hitachi Energy
- Publisher
- Hitachi Energy
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Publisher landing page opened with TinyFish on 2026-11-16. No explicit open licence or commercial redistribution grant was displayed in the retrieved page; retained as metadata and original summary only. Free access or a download button is not permission to redistribute. Publisher landing page opened. Linked digitalassets page returned empty content; full brief access remains unverified and the access field describes the free public overview only. License evidence: https://go.hitachienergy.com/USDataCenterAI
Citation
Hitachi Energy Powering data centers sustainably in an AI world: Artificial Intelligence - Friend or Foe of Sustainable Data Centers?. Hitachi Energy. https://go.hitachienergy.com/USDataCenterAI
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.