Research paperFree to read2015

Energy efficiency and air quality considerations in airside economized data centers

IBM Research / InterPACK 2015 · Levente J. Klein, Sergio A. Bermudez et al.

An IBM Research InterPACK 2015 paper on gaseous pollutant corrosion risk in free air cooling and its monitoring with ultra-high-sensitivity corrosion sensors, with a feasibility study of eight legacy data centers.

On this page

Overview

The InterPACK 2015 paper by Levente J. Klein, Sergio A. Bermudez, F. Marianno, Hendrik Hamann and Prabjit Singh notes that many operators are considering converting from mechanical to free air cooling. The main advantage is that chiller and air conditioning unit operation is eliminated when outdoor temperature falls below the data center set point.

The main concerns are accidental introduction of gaseous pollutants along the fresh air and possible latency of the control infrastructure in response to extreme events. The paper describes how ultra-high-sensitivity corrosion sensors allow real-time air quality monitoring and a better understanding of how airflow, relative humidity and temperature fluctuations affect corrosion rates, and how sensor sensitivity and wireless networks' ability to detect and react rapidly make them reliable tools for preventing corrosion-related failures. A feasibility study evaluates eight legacy data centers for implementing free air cooling.

Key points

  1. Free air cooling eliminates chiller and air conditioning unit operation when outdoor temperature is below the set point.
  2. Main concerns are accidental gaseous pollutant ingress and control latency in extreme events.
  3. Ultra-high-sensitivity corrosion sensors enable real-time air quality monitoring.
  4. Sensor data shows how airflow, relative humidity and temperature fluctuations affect corrosion rates.
  5. A feasibility study covers eight legacy data centers.

Using it in design

  • For free-cooled sites, define air quality and corrosion monitoring points at design stage.
  • Define a control and damper strategy that responds quickly to pollutant events at the outside air intake.
  • Assess an existing hall's suitability for free air using corrosion sensor measurements and climate data in the feasibility stage.

Who should read it

Mechanical designers and operators evaluating free air or airside economizer applications.

Publication details

Authors
Levente J. Klein; Sergio A. Bermudez; F. Marianno; Hendrik Hamann; Prabjit Singh
Publisher
IBM Research / InterPACK 2015
Year
2015
Document number
InterPACK 2015
Document language
English
Source type
Scientific
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official author institution, repository or publisher page inspected. No article-specific redistribution permission established; metadata and original brief summaries only. Free access may refer to the public abstract, not the full paper.

Citation

Levente J. Klein; Sergio A. Bermudez; F. Marianno; Hendrik Hamann; Prabjit Singh (2015). Energy efficiency and air quality considerations in airside economized data centers. IBM Research / InterPACK 2015. InterPACK 2015. https://doi.org/10.1115/IPACK2015-48349

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.