RFC 9014: Interconnect Solution for Ethernet VPN (EVPN) Overlay Networks

Internet Engineering Task Force (IETF) / RFC Editor · J. Rabadan, S. Sathappan et al.

A 2021 IETF Standards Track RFC defining decoupled and integrated gateway models, and Interconnect Ethernet Segment (I-ES) multihoming, for connecting EVPN data-centre overlays to WANs running VPLS, PBB-VPLS, EVPN or PBB-EVPN.

On this page

Overview

RFC 9014 describes how network virtualization overlays (NVOs) can be connected to a WAN to extend the Layer 2 connectivity some tenants require. It analyses the interaction between NVO networks running EVPN and other L2VPN technologies used in the WAN (VPLS, PBB-VPLS, EVPN, PBB-EVPN), shows how existing specifications apply and extends EVPN procedures where needed. In particular it describes how EVPN routes are processed on gateways (GWs) joining EVPN-Overlay and EVPN-MPLS networks, and the Interconnect Ethernet Segment (I-ES) for multihoming.

The decoupled architecture suits networks where the EVPN-Overlay and WAN providers are different entities and a clear demarcation is needed. Requirements: a simple handoff that makes QoS and security enforcement easy, independence from the WAN L2VPN technology, per-service load-balanced multihoming between GW and WAN edge routers (per-flow balancing is not a strong requirement), Ethernet OAM and CFM between GW and WAN edge to detect circuit failures, and GW optimisations: reducing unknown-unicast flooding, controlling WAN MAC advertisement, and controlling ARP/ND flooding from the WAN. VLAN-based and pseudowire-based handoffs are defined.

In the integrated architecture the GW speaks the WAN protocol directly, with VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN and EVPN-VXLAN interconnects in separate sections. The EVPN-MPLS interconnect is listed as having benefits over the DCI-using-ASBRs solution: local attachment circuits on the GW, different data-plane encapsulations in DC and WAN, independent inclusive multicast trees, MPLS label aggregation (a remote PE receives one label per GW MAC-VRF instead of one per NVE), and MAC mobility procedures on the GW only for mobility across data centres.

For EVPN-VXLAN interconnect, VXLAN has no ESI label, so Local Bias handles split horizon. VNIs are either globally unique within a data centre and translated at the GW, or downstream-assigned. The document also defines the Unknown MAC Route (UMR) to reduce MAC scale on NVE devices, and contains security and IANA considerations.

Key points

  1. A 2021 Standards Track RFC; connects EVPN-Overlay networks to VPLS, PBB-VPLS, EVPN and PBB-EVPN WANs.
  2. The decoupled architecture gives a clear demarcation when DC and WAN providers differ and is independent of the WAN L2VPN technology.
  3. Per-service load-balanced multihoming between GW and WAN edge is required; per-flow balancing is not strong because a deterministic path per service eases QoS and security enforcement.
  4. Ethernet OAM and CFM are needed between GW and WAN edge to detect individual circuit failures.
  5. GW optimisations: reduce unknown-unicast flooding, control WAN MAC advertisement, control ARP/ND flooding from the WAN.
  6. Integrated models: VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN and EVPN-VXLAN interconnects.
  7. EVPN-MPLS interconnect beats DCI using ASBRs on local circuits, differing encapsulations, independent multicast trees and MPLS label aggregation.
  8. The Unknown MAC Route (UMR) avoids MAC scale issues on DC NVEs; Local Bias is used for VXLAN.

Using it in design

  • Choose the decoupled model when DC and WAN are different providers and the integrated model when one operator runs both; document the responsibility split at the boundary.
  • Design GW multihoming as per-service load-balanced and add OAM and CFM to the device requirements for circuit-failure detection.
  • Plan to limit NVE MAC table scale with UMR or GW MAC advertisement control.
  • For EVPN-VXLAN interconnect, choose the VNI plan (globally unique with GW translation, or downstream-assigned) up front.
  • Add the GW policy that controls ARP/ND flooding from the WAN to the configuration template.

Who should read it

Network architects designing multi-site data-centre L2 extension and engineers defining the boundary interface with WAN providers.

Document contents

  1. Introduction
  2. Conventions and Terminology
  3. Decoupled Interconnect Solution for EVPN-Overlay Networks: requirements, VLAN-based handoff, PW-based handoff, multihoming on GWs, gateway optimisations
  4. Integrated Interconnect Solution for EVPN-Overlay Networks: VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN, EVPN-VXLAN interconnect
  5. Security Considerations
  6. IANA Considerations

Publication details

Authors
J. Rabadan; S. Sathappan; W. Henderickx; A. Sajassi; J. Drake
Publisher
Internet Engineering Task Force (IETF) / RFC Editor
Year
2021
Document number
RFC 9014
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public official source inspected. No document-specific commercial redistribution permission established. Metadata and original brief summaries only; local evidence is not a redistribution package. Document invokes BCP 78 / IETF Trust terms. General redistribution clearance was not evaluated in this pass.

Citation

J. Rabadan; S. Sathappan; W. Henderickx; A. Sajassi; J. Drake (2021). RFC 9014: Interconnect Solution for Ethernet VPN (EVPN) Overlay Networks. Internet Engineering Task Force (IETF) / RFC Editor. RFC 9014. https://doi.org/10.17487/RFC9014

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.