RFC 9014: Interconnect Solution for Ethernet VPN (EVPN) Overlay Networks
Internet Engineering Task Force (IETF) / RFC Editor · J. Rabadan, S. Sathappan et al.
A 2021 IETF Standards Track RFC defining decoupled and integrated gateway models, and Interconnect Ethernet Segment (I-ES) multihoming, for connecting EVPN data-centre overlays to WANs running VPLS, PBB-VPLS, EVPN or PBB-EVPN.
On this page
Overview
RFC 9014 describes how network virtualization overlays (NVOs) can be connected to a WAN to extend the Layer 2 connectivity some tenants require. It analyses the interaction between NVO networks running EVPN and other L2VPN technologies used in the WAN (VPLS, PBB-VPLS, EVPN, PBB-EVPN), shows how existing specifications apply and extends EVPN procedures where needed. In particular it describes how EVPN routes are processed on gateways (GWs) joining EVPN-Overlay and EVPN-MPLS networks, and the Interconnect Ethernet Segment (I-ES) for multihoming.
The decoupled architecture suits networks where the EVPN-Overlay and WAN providers are different entities and a clear demarcation is needed. Requirements: a simple handoff that makes QoS and security enforcement easy, independence from the WAN L2VPN technology, per-service load-balanced multihoming between GW and WAN edge routers (per-flow balancing is not a strong requirement), Ethernet OAM and CFM between GW and WAN edge to detect circuit failures, and GW optimisations: reducing unknown-unicast flooding, controlling WAN MAC advertisement, and controlling ARP/ND flooding from the WAN. VLAN-based and pseudowire-based handoffs are defined.
In the integrated architecture the GW speaks the WAN protocol directly, with VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN and EVPN-VXLAN interconnects in separate sections. The EVPN-MPLS interconnect is listed as having benefits over the DCI-using-ASBRs solution: local attachment circuits on the GW, different data-plane encapsulations in DC and WAN, independent inclusive multicast trees, MPLS label aggregation (a remote PE receives one label per GW MAC-VRF instead of one per NVE), and MAC mobility procedures on the GW only for mobility across data centres.
For EVPN-VXLAN interconnect, VXLAN has no ESI label, so Local Bias handles split horizon. VNIs are either globally unique within a data centre and translated at the GW, or downstream-assigned. The document also defines the Unknown MAC Route (UMR) to reduce MAC scale on NVE devices, and contains security and IANA considerations.
Key points
- A 2021 Standards Track RFC; connects EVPN-Overlay networks to VPLS, PBB-VPLS, EVPN and PBB-EVPN WANs.
- The decoupled architecture gives a clear demarcation when DC and WAN providers differ and is independent of the WAN L2VPN technology.
- Per-service load-balanced multihoming between GW and WAN edge is required; per-flow balancing is not strong because a deterministic path per service eases QoS and security enforcement.
- Ethernet OAM and CFM are needed between GW and WAN edge to detect individual circuit failures.
- GW optimisations: reduce unknown-unicast flooding, control WAN MAC advertisement, control ARP/ND flooding from the WAN.
- Integrated models: VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN and EVPN-VXLAN interconnects.
- EVPN-MPLS interconnect beats DCI using ASBRs on local circuits, differing encapsulations, independent multicast trees and MPLS label aggregation.
- The Unknown MAC Route (UMR) avoids MAC scale issues on DC NVEs; Local Bias is used for VXLAN.
Using it in design
- Choose the decoupled model when DC and WAN are different providers and the integrated model when one operator runs both; document the responsibility split at the boundary.
- Design GW multihoming as per-service load-balanced and add OAM and CFM to the device requirements for circuit-failure detection.
- Plan to limit NVE MAC table scale with UMR or GW MAC advertisement control.
- For EVPN-VXLAN interconnect, choose the VNI plan (globally unique with GW translation, or downstream-assigned) up front.
- Add the GW policy that controls ARP/ND flooding from the WAN to the configuration template.
Who should read it
Network architects designing multi-site data-centre L2 extension and engineers defining the boundary interface with WAN providers.
Document contents
- Introduction
- Conventions and Terminology
- Decoupled Interconnect Solution for EVPN-Overlay Networks: requirements, VLAN-based handoff, PW-based handoff, multihoming on GWs, gateway optimisations
- Integrated Interconnect Solution for EVPN-Overlay Networks: VPLS, PBB-VPLS, EVPN-MPLS, PBB-EVPN, EVPN-VXLAN interconnect
- Security Considerations
- IANA Considerations
Publication details
- Authors
- J. Rabadan; S. Sathappan; W. Henderickx; A. Sajassi; J. Drake
- Publisher
- Internet Engineering Task Force (IETF) / RFC Editor
- Year
- 2021
- Document number
- RFC 9014
- Document language
- English
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Public official source inspected. No document-specific commercial redistribution permission established. Metadata and original brief summaries only; local evidence is not a redistribution package. Document invokes BCP 78 / IETF Trust terms. General redistribution clearance was not evaluated in this pass.
Citation
J. Rabadan; S. Sathappan; W. Henderickx; A. Sajassi; J. Drake (2021). RFC 9014: Interconnect Solution for Ethernet VPN (EVPN) Overlay Networks. Internet Engineering Task Force (IETF) / RFC Editor. RFC 9014. https://doi.org/10.17487/RFC9014
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.