RFC 9816: Usage and Applicability of BGP Link State (BGP-LS) Shortest Path First (SPF) Routing in Data Centers

IETF / RFC Editor · K. Patel, A. Lindem et al.

An IETF Informational RFC (July 2025) explaining how RFC 9815's BGP-LS SPF extensions apply in Clos and Fat Tree data-centre networks, with simplified guidance including sparse peering and DCI.

On this page

Overview

RFC 9816 is an Informational document on using the RFC 9815 extensions in data-centre networks with Clos or Fat Tree topologies; it is not a Standards Track specification. Its purpose is simplified guidance for deploying BGP-LS SPF. The justification is that path-vector BGP in a Clos relies on hop-by-hop eBGP peering, which prohibits route reflectors and controllers because the eBGP sessions are congruent with the data path, and the prefix-based best-path algorithm prevents announcement until a decision is made at each hop, which delays convergence.

The document explains use of the BGP-LS-SPF SAFI and its relation to other BGP AFI/SAFI tuples. Among peering models, sparse peering stands out: BGP-SPF sessions need only be established with enough peers to provide a biconnected graph; with iBGP, routers at tier N-1 act as route reflectors for tier N. In dense topologies with 32-way or 64-way ECMP between leaf and spine, sessions are not set on every link and each leaf peers with a subset of spines.

Further sections cover BGP peer discovery (including IPv6 simplified peering), BGP-LS-SPF topology visibility for management, DCI applicability, use in non-Clos topologies, the non-transit node capability and BGP policy applicability. Controllers can learn the topology from the BGP-SPF advertisements, so each router no longer needs to advertise its BGP-LS information separately.

Key points

  1. Published in July 2025 as Informational; not a Standards Track specification and a companion to RFC 9815.
  2. Scope explicitly addresses Clos and Fat Tree topologies; a separate section covers non-Clos topologies.
  3. Hop-by-hop eBGP in path-vector BGP prevents route reflectors and controllers and delays convergence.
  4. In sparse peering, sessions need only form a biconnected graph.
  5. With iBGP, tier N-1 routers can act as route reflectors for tier N.
  6. In topologies with 32-way or 64-way ECMP between leaf and spine, a session on every link is not wanted.
  7. Controllers learn topology from BGP-SPF advertisements; separate BGP-LS advertisement is not needed.
  8. DCI applicability, non-transit node capability and BGP policy are each covered in separate sections.

Using it in design

  • To reduce session count in a Clos fabric, design the sparse peering rule (biconnected graph) and decide which subset of spines each leaf peers with.
  • If a controller-based topology is considered, record controller placement (in or out of the forwarding path) and redundancy in the design.
  • When setting convergence and flow requirements, compare against the limits of hop-by-hop eBGP peering.
  • Define non-transit behaviour and BGP policy for leaf and edge nodes in advance.
  • Read RFC 9815 (specification) together with this RFC (deployment guidance) when preparing the device compliance list.

Who should read it

Network architects designing Clos or Fat Tree data-centre fabrics and operations engineers aiming to simplify BGP routing.

Document contents

  1. Introduction
  2. Recommended Reading
  3. Common Deployment Scenario
  4. Justification for the BGP-SPF Extension
  5. BGP-SPF Applicability to Clos Networks: usage of BGP-LS-SPF SAFI, peering models (sparse peering, biconnected graph heuristic), spine/leaf policy, peer discovery, topology visibility, DCI applicability
  6. Non-Clos / Fat Tree Topology Applicability
  7. Non-Transit Node Capability
  8. BGP Policy Applicability
  9. IANA and Security Considerations

Related standards

  • RFC 9816

Publication details

Authors
K. Patel; A. Lindem; S. Zandi; G. Dawra; J. Dong
Publisher
IETF / RFC Editor
Year
2025
Document number
RFC 9816
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.

Citation

K. Patel; A. Lindem; S. Zandi; G. Dawra; J. Dong (2025). RFC 9816: Usage and Applicability of BGP Link State (BGP-LS) Shortest Path First (SPF) Routing in Data Centers. IETF / RFC Editor. RFC 9816. https://doi.org/10.17487/RFC9816

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.