Government Promotes Sustainable Growth of Data Centres through Energy-Efficient and Clean Energy Measures

Ministry of Electronics and Information Technology / Press Information Bureau, India

Indian PIB press release (12 August 2026): installed data-centre capacity grew from 375 MW in 2020 to about 1,575 MW, and CEA estimates about 17 GW of data-centre demand up to 2031-32.

On this page

Overview

The release from the Press Information Bureau (PIB) is based on the Ministry of Electronics and Information Technology's Rajya Sabha reply of 7 August 2026. It presents data centres as a component of the Digital India infrastructure ecosystem and says AI and high-performance computing are raising capacity demand. Data centres are concentrated in Mumbai, Navi Mumbai, Chennai, Hyderabad, Bengaluru, Delhi NCR and Jamnagar; Andhra Pradesh, Madhya Pradesh, Chhattisgarh and West Bengal are named as new investment destinations.

The figures: installed capacity has grown from 375 MW in 2020 to about 1,575 MW, which is under 1% of the country's installed power capacity. According to the Central Electricity Authority (CEA), data-centre power demand is estimated at about 17 GW up to 2031-32. The release lists renewable-promotion instruments such as the Green Energy Open Access Rules, Green Energy Corridor Scheme and Green Term Ahead Market (GTAM), and cites the SHANTI Act for reliable clean power for AI and data centres, including future small modular and micro nuclear reactors.

On standards and codes, the Bureau of Indian Standards technical committee LITD 31 has published a series of Indian Standards on PUE, Carbon Usage Effectiveness (CUE), Cooling Efficiency Ratio (CER) and Water Usage Effectiveness (WUE). BEE has notified ECBC 2017 and the Energy Conservation and Sustainable Building Code (ECSBC 2024) with provisions relevant to data centres. Water need depends on cooling technology, and groundwater extraction follows Ministry of Jal Shakti guidelines. The sector is adopting direct-to-chip liquid, adiabatic, immersion and closed-loop liquid cooling and high-density racks.

Key points

  1. Installed data-centre capacity was 375 MW in 2020 and is about 1,575 MW now, under 1% of national installed power.
  2. CEA estimate: data-centre power demand of about 17 GW up to 2031-32.
  3. Main hubs are Mumbai, Navi Mumbai, Chennai, Hyderabad, Bengaluru, Delhi NCR and Jamnagar; new destinations are Andhra Pradesh, Madhya Pradesh, Chhattisgarh and West Bengal.
  4. BIS committee LITD 31 has published Indian Standards on PUE, CUE, CER and WUE.
  5. BEE's ECBC 2017 and ECSBC 2024 set energy efficiency and water conservation norms, including provisions relevant to data centres.
  6. Renewable instruments: Green Energy Open Access Rules, Green Energy Corridor, GTAM, National Green Hydrogen Mission, Solar Park Scheme and others.
  7. The SHANTI Act covers reliable clean power for AI and data centres, including future small modular and micro nuclear reactors.
  8. Water need depends on cooling technology; groundwater extraction follows Ministry of Jal Shakti guidelines.
  9. The sector uses direct-to-chip, adiabatic, immersion and closed-loop liquid cooling and high-density racks.

Using it in design

  • For Indian projects, define PUE, CUE, CER and WUE targets against the BIS LITD 31 standards and write them into the measurement plan.
  • Include ECBC 2017 and ECSBC 2024 provisions in the envelope, cooling and water conservation design criteria.
  • Consider mechanisms such as Green Energy Open Access and GTAM as options for renewable supply.
  • Verify the power demand growth expectation (about 17 GW by 2031-32) locally in grid and transmission connection planning.
  • When selecting cooling technology, add Jal Shakti guidelines and state permits for water abstraction to the pre-feasibility.

Who should read it

Investors developing data centres in India, energy and environment compliance specialists and design teams.

Document contents

  1. Overview of the data-centre sector
  2. Capacity and power demand
  3. Energy efficiency and water conservation: renewable instruments, SHANTI Act, BIS standards, BEE codes
  4. Cooling technologies and high-density racks

Publication details

Authors
Ministry of Electronics and Information Technology / Press Information Bureau, India
Publisher
Ministry of Electronics and Information Technology / Press Information Bureau, India
Year
2026
Document number
PIB release 2298108, 12 August 2026
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public publisher text inspected. No document-specific commercial redistribution permission established; metadata and original short summaries only.

Citation

Ministry of Electronics and Information Technology / Press Information Bureau, India (2026). Government Promotes Sustainable Growth of Data Centres through Energy-Efficient and Clean Energy Measures. Ministry of Electronics and Information Technology / Press Information Bureau, India. PIB release 2298108, 12 August 2026. https://pib.gov.in/PressReleasePage.aspx?PRID=2298108&lang=1&reg=1

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.