Quality of Service Trade-offs Between Central Data Centers and Nano Data Centers
İstanbul Teknik Üniversitesi · Farzaneh Akhbar
A 2015 ITU M.Sc. thesis that uses CloudAnalyst simulation to compare a central data centre with nano data centres, finding a memory threshold of about 1 GB for best response time.
On this page
Overview
This M.Sc. thesis by Farzaneh Akhbar, submitted in May 2015 to the Computer Engineering programme at Istanbul Technical University, examines how replacing one central data centre with distributed nano data centres (NDCs) affects quality of service in cloud computing. The rationale is rapidly growing data volume and the difficulty central structures have in meeting consumer requests. It is a simulation study with no measurement on a real cloud architecture.
The method uses the CloudAnalyst simulator, written in Java on top of CloudSim. The central data centre (CDC) and nano data centres are compared while varying memory capacity, processor speed, bandwidth and the number of user bases sending requests to their local data centre. Nano data centres can request service from neighbours in peer-to-peer form. The metrics are response time and performance cost.
According to the results, nano data centres give better quality of service than the central structure even in the worst case. For memory capacity 1 GB is found as the threshold, and a memory ratio of 0.04 is the saturation point. The trade-off points between response time and performance cost are 200 user bases and a memory ratio of 0.02. No significant effect is found for processor speed and bandwidth; the roughly 50 ms response time reached beyond certain values is not applicable to real NDCs, so it is not treated as a saturation point.
The limits are explicit: simulation results are not validated on a real architecture, not repeated with other simulators, and cost effectiveness is not analysed in depth. The author proposes testing other communication modes between neighbouring data centres and studying larger numbers of data centres as next steps. The document offers academic background for the edge and distributed data centre concept rather than guidance for enterprise data centre design.
Key points
- The simulator is CloudAnalyst (Java, CloudSim-based); there is no real hardware or real cloud measurement.
- Nano data centres give better service quality than central data centres even in the worst case.
- The threshold value for memory capacity is found to be 1 GB.
- A memory ratio of 0.04 is the saturation point.
- The trade-off points between response time and performance cost are 200 user bases and a memory ratio of 0.02.
- No significant effect is found for processor speed and bandwidth.
- Compared properties are memory capacity, processor speed, bandwidth, number of user bases and data packet size.
- The thesis is dated May 2015; validation on a real NDC architecture is left as future work.
Using it in design
- In edge or micro data centre scenarios, treat local memory share as the main determinant of service quality; measure the memory threshold rather than oversizing processor and bandwidth.
- When comparing central and distributed topologies, use simulations that compute response time and performance cost together and identify the trade-off point.
- Do not treat simulation results as direct sizing data; validate them with your own workload.
- In distributed designs, add the network load of peer-to-peer service requests between neighbouring nodes to the capacity plan.
Who should read it
Engineers and academics exploring edge and distributed data centre concepts, and teams planning cloud architecture.
Document contents
- Introduction
- Literature Review
- Background
- Simulation Environment
- Simulation Results and Evaluation
- Conclusions and Future Work
Publication details
- Authors
- Farzaneh Akhbar
- Publisher
- İstanbul Teknik Üniversitesi
- Year
- 2015
- Document number
- M.Sc. thesis, Computer Engineering, May 2015
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official publisher or university publicly accessible text; no open redistribution licence established. University record dateissued is July 2015 while the thesis cover says May; year 2015 retained. Repository explicitly prohibits redistribution without permission.
Citation
Farzaneh Akhbar (2015). Quality of Service Trade-offs Between Central Data Centers and Nano Data Centers. İstanbul Teknik Üniversitesi. M.Sc. thesis, Computer Engineering, May 2015. https://polen.itu.edu.tr/bitstreams/618985b5-cb5c-446c-b62f-5af1f3c8e194/download