Research paperFree to read2026

Noise Exposure Assessment in the Occupational Environment of Air-Cooled Data Centers

Architectural Institute of Korea / KoreaScience · Jinkyun Cho, Hansol Lim et al.

A 2026 Architectural Institute of Korea paper is a field case study comparing sound level, frequency spectrum and acoustic-camera measurements in hot- and cold-aisle containment of an operational air-cooled data centre.

On this page

Overview

The paper, published in the Journal of the Architectural Institute of Korea (42(1), 273-281, DOI 10.5659/JAIK.2026.42.1.273), is a field case study of the acoustic environment for workers in air-cooled data centres. Its English abstract describes a comparison of acoustic conditions in hot- and cold-aisle containment of an operational facility.

Measurements use sound level, frequency spectrum and acoustic camera; A-weighted equivalent levels and C-weighted peaks were taken at standing and seated ear heights.

Key points

  1. Field case study of an operational air-cooled data centre.
  2. Acoustic conditions in hot- and cold-aisle containment are compared.
  3. Measurements include sound level, frequency spectrum and acoustic camera.
  4. A-weighted equivalent levels and C-weighted peaks are measured.
  5. Measurements were taken at standing and seated ear heights.

Using it in design

  • In containment design define the A-weighted equivalent level and C-weighted peak in work areas as design targets.
  • Plan acoustic measurement points at hot- and cold-aisle entrances at standing and seated ear heights.
  • Use acoustic camera and spectrum measurement to locate dominant noise sources such as fans and CRAH units.
  • Add hearing protection and exposure-time procedures to the operations file.

Who should read it

Engineers carrying out data-centre acoustic and occupational health assessments, and facility managers.

Related standards

  • ISO 9612

Publication details

Authors
Jinkyun Cho; Hansol Lim; Sangwoo Byeon; Haram Kim
Publisher
Architectural Institute of Korea / KoreaScience
Year
2026
Document number
42(1), 273–281
Document language
Korean
Source type
Scientific
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Publisher-hosted KoreaScience abstract and metadata opened; Korean full text not read. language=ko follows citation_language. No open licence established. Only original study methods summarized, not cited ASHRAE material.

Citation

Jinkyun Cho; Hansol Lim; Sangwoo Byeon; Haram Kim (2026). Noise Exposure Assessment in the Occupational Environment of Air-Cooled Data Centers. Architectural Institute of Korea / KoreaScience. 42(1), 273–281. https://doi.org/10.5659/JAIK.2026.42.1.273

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.