12th International Conference on Improving Energy Efficiency in Commercial Buildings and Smart Communities (Proceedings)
Original title 12th International Conference on Improving Energy Efficiency in Commercial Buildings and Smart Communities
Publications Office of the European Union / Joint Research Centre · Enrico Clementi, Paolo Bertoldi
The 2024 JRC proceedings collect nine papers from the March 2024 Frankfurt conference; the data-centre paper shows an edge data centre carrying a 20 A load while limiting grid draw to 16 A.
On this page
Overview
The volume collects nine papers based on presentations at the IEECB&SC'24 and European ESCO conference held in Frankfurt on 6-7 March 2024. The editors are Clementi and Bertoldi; it is a Publications Office of the European Union document, JRC137722, under a CC BY 4.0 licence. The conference scope is energy efficiency, renewable energy and greenhouse-gas reduction in non-residential buildings, ICT and data centres, and districts and cities.
Most papers deal with topics outside data centres: a compact integrated thermal energy storage system (MiniStor), a 25-year review of the NABERS programme, commercial building efficiency measures for the Australian National Construction Code, machine learning in urban building energy modelling, the widening gap between brown and green buildings, smart lighting, MEPS implementation in lighting, and positive energy district (PED) case studies.
The paper of interest to a data-centre designer is the sixth: risk-aware resource planning for an edge data centre connected to a microgrid with renewable production under grid power constraints, by Brännvall and colleagues of RISE and Ericsson Research. The method expresses solar production through a probabilistic model conditioned on the weather forecast, allowing planning with confidence intervals. The architecture is built around a bidirectional AC/DC UPS component that can use battery, grid and photovoltaic power flexibly.
The simulation shows that a small microgrid-connected edge data centre can carry a 20 A computational load all day while limiting grid draw to 16 A over a 12-hour window, without exhausting the battery at 95% confidence. The authors leave validation of the model against historical data to future work. The volume is not a general data-centre guide; its data-centre content is limited to one paper.
Key points
- The conference took place in Frankfurt on 6-7 March 2024; the volume is JRC137722 dated 3 June 2024, DOI 10.2760/716916.
- There are nine papers; only the sixth is directly about data centres.
- Paper 6: risk-aware resource planning for a microgrid-connected edge data centre with renewable production and a grid power constraint.
- In simulation a 20 A computational load is carried all day while grid draw is limited to 16 A over a 12-hour window, with the battery not exhausted at 95% confidence.
- Solar production is tied to the weather forecast by a probabilistic model built from clear-sky models and local weather-station observations.
- The architecture uses a bidirectional AC/DC UPS component (the Rectiverter) to make battery, grid and photovoltaic use flexible.
- MiniStor thermal storage paper: storage density above 200 kWh/m3, a 7.68 kWh Li-ion battery, and 63% of the daily thermal load covered on average.
- The other papers cover NABERS, the Australian construction code, urban building energy modelling, lighting and PED case studies.
Using it in design
- For edge or small sites with limited grid connection, set committed compute capacity with a confidence interval (for example 95%) rather than deterministically.
- For PV and battery supported edge sites, choose a bidirectional UPS component able to manage grid, battery and solar inputs.
- Define the grid limit current (for example 16 A) and the compute load current (for example 20 A) as separate parameters and verify them with a battery state-of-charge simulation.
- Back-test the simulation model against local weather and load data before relying on it; the paper leaves this validation to future work.
Who should read it
Edge data-centre and microgrid designers, and engineers and policy analysts following commercial-building energy-efficiency policy.
Document contents
- 1 Analysis of a novel compact integrated thermal energy storage system (MiniStor) in European sites
- 2 NABERS Nearly 25 years on - Program Overview
- 3 Commercial Building Energy Efficiency Measures for the Australian National Construction Code: Preliminary Results
- 4 Machine Learning algorithms for Urban Building Energy Modeling
- 5 Quantifying the Growing Gap Between Brown and Green Buildings
- 6 Risk aware resource planning for microgrid connected edge data center with renewable energy production operating under grid power constraints
- 7 Smart Lighting systems: Dream or reality?
- 8 Energy efficiency in lighting based on the implementation of MEPS
- 9 Lessons learned from analysing PED case studies
Publication details
- Authors
- Enrico Clementi; Paolo Bertoldi
- Publisher
- Publications Office of the European Union / Joint Research Centre
- Year
- 2024
- Document number
- JRC137722
- Document language
- English
- Source type
- Government / public
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
JRC publisher landing page opened with TinyFish 2026-11-16. Extraction includes contradictory generic visibility notices; PDF copyright page could not be accessed. No document-specific open licence confirmed, so citation-only. Portal reuse notice also opened: https://op.europa.eu/en/web/about-us/legal-notices/publications-office-of-the-european-union-copyright requires checking each publication's notice.
Citation
Enrico Clementi; Paolo Bertoldi (2024). 12th International Conference on Improving Energy Efficiency in Commercial Buildings and Smart Communities. Publications Office of the European Union / Joint Research Centre. JRC137722. https://doi.org/10.2760/716916
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.