KühlTherm RDHx ProSeries Overview

Original title RDHx ProSeries and modular liquid-cooling overview

KühlTherm

The KühlTherm RDHx ProSeries rear door heat exchanger scales in 20 kW blocks to 100 kW per door; the same family includes a CDU scaling in 250 kW blocks to 1.5 MW and 300-2500 W cold plates.

On this page

Overview

KühlTherm (Ahmedabad, India) offers full-stack liquid cooling from chip to chiller for AI and GPU infrastructure. The RDHx ProSeries rear door heat exchanger captures heat at the rear of the rack before it enters the data-centre environment, using variable speed fans and built-in redundancy to follow real-time thermal load. The modular architecture scales from 20 kW to 100 kW per door.

The family includes the CDU (250 kW blocks up to 1.5 MW per row, with leak-free connections and redundancy), direct liquid cooling with patented Mesh Cold Plate (300-2500 W per plate, rack densities beyond 100 kW) and NexusFlow OS software. N+1 redundant pumps and fans, automated leak isolation and toolless service are stated. The page gives module increments and does not establish separate model numbers.

Key points

  1. RDHx scales from 20 kW to 100 kW per door in 20 kW blocks.
  2. The CDU scales in 250 kW blocks to 1.5 MW per row.
  3. Mesh Cold Plate delivers 300-2500 W per plate for racks beyond 100 kW.
  4. N+1 redundant pumps and fans, automated leak isolation and toolless service.
  5. NexusFlow OS provides chip-to-chiller and grid-to-rack monitoring.

Using it in design

  • Match rear door capacity to rack heat load in 20 kW block steps.
  • Size the CDU in 250 kW blocks and check the 1.5 MW per row limit.
  • Because capacity is stated in module increments rather than model codes, request the capacity table from the manufacturer.
  • Show N+1 pumps and fans as separate items in the redundancy scheme.

Who should read it

Data-centre designers evaluating rear door heat exchangers and CDUs for high-density AI racks.

Publication details

Authors
KühlTherm
Publisher
KühlTherm
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

KühlTherm RDHx ProSeries and modular liquid-cooling overview. KühlTherm. https://www.kuhltherm.com/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.