Research paperFree to read2024

Turning Data Center Waste Heat into Energy: A Guide to Organic Rankine Cycle System Design and Performance Evaluation

Applied Sciences (MDPI AG) · Orlando Corigliano, Angelo Algieri et al.

A 2024 Applied Sciences guide designs an organic Rankine cycle (ORC) that turns data-centre waste heat into electricity, with net efficiency of 3.1-7.1% for pentane and 3.6-7.0% for isopentane.

On this page

Overview

The study examines adopting the organic Rankine cycle (ORC) for recovering data-centre waste heat. A literature review covers energy reuse focused on electric power generation, working fluid selection and system design principles. The objective is a thorough design and analysis framework that begins with an investigation of the quantity and quality of available waste heat. Air cooling accounts for about 70% of cooling methods used; water cooling is more effective but less commonly adopted.

In a conceptual case study the system is designed and simulated in the DWSIM environment. The model uses hot air or hot liquid water returning from the data-centre cooling system to evaporate the ORC working fluid, with ambient water for condensing. Pentane and isopentane are identified as suitable organic fluids.

Pentane gives net electric efficiencies of 3.1-7.1% as operating pressure ratios rise from 2.8 to 6.4; isopentane systems reach 3.6-7.0% across pressure ratios of 2.7-6.0. The study reports PUE, energy reuse factor (ERF), energy reuse effectiveness (ERE) and GHG savings for a reference data centre, and ends with analysis guidelines including exergy considerations and the sizing process for evaporators and condensers.

Key points

  1. Air cooling accounts for about 70% of cooling methods used.
  2. Water cooling is more effective but less commonly adopted.
  3. Pentane ORC net electric efficiency is 3.1-7.1% at pressure ratios of 2.8-6.4.
  4. Isopentane ORC efficiency is 3.6-7.0% at pressure ratios of 2.7-6.0.
  5. Simulation is done in DWSIM; the evaporator uses hot air or hot water and the condenser uses ambient water.
  6. PUE, ERF, ERE and GHG savings are reported for a reference data centre.

Using it in design

  • When evaluating electricity generation from waste heat, compare the 3-7% net efficiency with alternatives such as heat sales.
  • Select the working fluid within the heat source and cold source temperature limits; pentane and isopentane are candidate fluids.
  • Report the effect of a recovery project with PUE, ERF and ERE together.
  • For liquid-cooled designs, test through simulation how a higher return temperature affects ORC efficiency.

Who should read it

Energy engineers evaluating electricity generation from waste heat, data-centre designers and researchers.

Related standards

  • The Green Grid ERE
  • ISO/IEC 30134-6 (ERF)

Publication details

Authors
Orlando Corigliano; Angelo Algieri; Petronilla Fragiacomo
Publisher
Applied Sciences (MDPI AG)
Year
2024
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Publisher-deposited Crossref licence metadata: https://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Orlando Corigliano; Angelo Algieri; Petronilla Fragiacomo (2024). Turning Data Center Waste Heat into Energy: A Guide to Organic Rankine Cycle System Design and Performance Evaluation. Applied Sciences (MDPI AG). https://doi.org/10.3390/app14146046

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.