Research paperFree to read2026

Carbon Accounting and Beyond: An Evidence-Based Life Cycle Assessment of the Environmental Impacts of Data Center IT Equipment

Sustainability (MDPI AG) · Meghann Smith, Manveer Mann et al.

A 2026 Sustainability (MDPI) study finds LCA of data-centre IT equipment gives 0.710 kg CO2e/kWh, versus 0.723 for average-data and 1.07 for spend-based accounting.

On this page

Overview

The study compares LCA-based estimates of data-centre IT equipment impacts with the two corporate GHG accounting methods in common use, average-data and spend-based. Its starting point is that regulations require operators to report electricity use and emissions, while methods for indirect sources remain insufficient.

Impacts are modelled at both grouped and granular levels to support enterprise-wide reporting and operational decisions. Sensitivity and uncertainty analyses test the robustness of the LCA models, and scenario analysis examines abatement strategies such as on-site renewable generation and operation on a low-carbon grid.

The LCA approach yields 0.710 kg CO2e/kWh and also surfaces burdens that carbon-only metrics miss. The average-data method is close at 0.723, while the spend-based method is substantially higher at 1.07 kg CO2e/kWh because of volatile market prices. Grid decarbonisation is the most effective mitigation pathway, though the scenarios also show trade-offs across impact categories.

Key points

  1. The LCA approach gives 0.710 kg CO2e/kWh.
  2. The average-data method is close, at 0.723 kg CO2e/kWh.
  3. The spend-based method is substantially higher at 1.07 kg CO2e/kWh, attributed to volatile market prices.
  4. Grid decarbonisation is the most effective mitigation pathway; on-site renewable generation is among the scenarios tested.
  5. LCA reveals additional environmental burdens that carbon-only metrics do not capture, and shows trade-offs across impact categories.

Using it in design

  • When reporting embodied emissions of IT equipment, prefer product-data LCA or the average-data method over spend-based accounting.
  • In abatement scenario comparisons, include grid carbon intensity as the main sensitivity parameter.
  • State the accounting method and the uncertainty range in the emissions report table.

Who should read it

Analysts producing data-centre sustainability reports, energy managers and decision makers choosing an emissions accounting method.

Related standards

  • GHG Protocol
  • ISO 14040/14044

Publication details

Authors
Meghann Smith; Manveer Mann; Pankaj Lal
Publisher
Sustainability (MDPI AG)
Year
2026
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Publisher-deposited Crossref licence metadata: https://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Meghann Smith; Manveer Mann; Pankaj Lal (2026). Carbon Accounting and Beyond: An Evidence-Based Life Cycle Assessment of the Environmental Impacts of Data Center IT Equipment. Sustainability (MDPI AG). https://doi.org/10.3390/su18115671

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.