Target Maturity Levels and Data Centre Tier Target (Central Bank of Nigeria IT Standards)
Original title Target Maturity Levels: Data Centre Maturity
Central Bank of Nigeria
The Central Bank of Nigeria's IT standards page sets a minimum Level 3 maturity for financial services and a Tier 3 data centre target (99.982% availability) based on TIA-942 and Uptime.
On this page
Overview
The page is the Target Maturity Levels section of the IT Standards Blueprint under the Nigeria Financial Services Shared IT Infrastructure and IT Standards Programme. Maturity levels indicate how robustly policies are formally articulated and how far they are assimilated into organisational practice, and they derive from commonly accepted IT standard models. Six levels are defined: 0 non-existent, 1 ad hoc, 2 repeatable, 3 defined, 4 managed and measurable, 5 optimised. The minimum target maturity for the financial services industry is Level 3. This level requires that standards are defined, documented, integrated into organisational practice through policy and procedure, and communicated through training, with automation and tools used in a limited and fragmented way.
The data centre section names TIA-942 and the Uptime Institute standards as reference for data centre infrastructure and environment, and covers primary data centres hosting live production as well as backup and disaster recovery locations. The tier table is adapted from those standards: Tier 1 has numerous single points of failure and can sustain at most a 10-minute power outage, Tier 2 adds generator backup and 24 hours, Tier 3 two utility paths and 72 hours, Tier 4 two independent utility paths and 96 hours. The target is Tier 3.
The page is a short policy document; the table values are summarised, adapted statements and do not replace the Uptime or TIA-942 text. It gives no electrical, cooling or fire design detail, but states clearly the level and outage endurance that financial institutions' data centre design should target.
Key points
- Maturity levels run from 0 (non-existent) to 5 (optimised); the minimum target for financial services is Level 3.
- Level 3 requires standards to be defined, documented, integrated through policy and communicated through training.
- Data centre references are TIA-942 and the Uptime Institute; backup and disaster recovery locations are also covered.
- Tier 1: numerous single points of failure; generally unable to sustain more than a 10-minute power outage.
- Tier 2: some redundancy in power and cooling, generator backup, 24-hour outage endurance, vapour barrier and a separate data room.
- Tier 3: two utility paths (active and passive), redundant power and cooling, redundant service providers, 72-hour endurance, one-hour fire rating and concurrent maintenance.
- Tier 4: two independent utility paths, independently dual-powered cooling, 96-hour endurance, minimum two-hour fire rating and 24/7 onsite maintenance staff.
- The target is Tier 3, which supports 99.982% availability.
Using it in design
- For Nigerian financial-sector clients, design the data centre to at least concurrently maintainable (Tier 3): two utility paths, redundant power and cooling, redundant service providers.
- Size fuel storage and generator capacity for a 72-hour power outage endurance target.
- Write the one-hour fire rating and careful site selection criteria into the design input.
- Verify that backup and disaster recovery locations also meet the same Tier target.
- For compliance audit, add Level 3 maturity evidence (documented procedures, training, policy) to the operating file.
Who should read it
Engineers and compliance managers designing or hosting data centres for the Nigerian financial sector.
Document contents
- Target Maturity Levels
- Data Centre Maturity and Tier levels
Publication details
- Authors
- Central Bank of Nigeria
- Publisher
- Central Bank of Nigeria
- Year
- Year not stated
- Document language
- English
- Source type
- Government / public
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Public official source inspected. No document-specific commercial redistribution permission established. Metadata and original brief summaries only; local evidence is not a redistribution package.
Citation
Central Bank of Nigeria Target Maturity Levels: Data Centre Maturity. Central Bank of Nigeria. https://www.cbn.gov.ng/itstandards/Target.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.