Technical guideFree to read2025

Implementing a Zero Trust Architecture (NIST SP 1800-35, High-Level Document)

Original title Implementing a Zero Trust Architecture: High-Level Document

NIST · Scott Rose, Oliver Borchert et al.

The June 2025 NIST NCCoE guide SP 1800-35 summarises 19 zero trust architecture example builds made from commercial products with 24 collaborators, findings on EIG, SDP, microsegmentation and SASE, and six functional use cases.

On this page

Overview

The document is the high-level summary of a NIST Cybersecurity Practice Guide explaining how to implement a zero trust architecture (ZTA) consistent with the principles of NIST SP 800-207. Working with 24 technology providers under cooperative agreements, the NCCoE built 19 example ZTA implementations in a lab using commercially available technology. Detailed technical information is in the full web-format document.

The guide defines ZTA as a risk-based architecture designed to prevent data breaches and limit internal lateral movement: conditions and requests are continuously evaluated and verified, and each access is safeguarded in proportion to risk. Implementations cover enhanced identity governance (EIG, crawl and run phases), software-defined perimeter (SDP), microsegmentation and SASE approaches. Reference architectures and builds are described in separate sections.

General findings list the fundamental capabilities for deciding whether to grant a request and let a session persist: authentication and periodic reauthentication of the user, the requesting endpoint and the endpoint hosting the resource, with authorisation. Health verification of the requesting and hosting endpoints is highly desirable. In the EIG crawl phase, many vendor solutions did not integrate out of the box well enough for ICAM to act as policy decision point, and the identity and health of the resource-hosting endpoint were not checked.

Six use cases were demonstrated functionally: discovery and identification, enterprise-ID access, federated-ID collaboration, other-ID access, guest (no-ID) access and confidence level. The guide also maps to SP 800-53r5 and NIST CSF 1.1 and 2.0. It is not data-centre specific but can inform planning a zero trust transition for management and operations network access.

Key points

  1. The NCCoE worked with 24 technology providers and built 19 example ZTA implementations with commercial technology.
  2. Approaches covered are EIG (enhanced identity governance), SDP, microsegmentation and SASE.
  3. Fundamental capabilities: authentication and periodic reauthentication of the user, the requesting endpoint and the resource-hosting endpoint.
  4. Health verification and periodic reverification of both endpoints is a highly desirable capability.
  5. In the EIG crawl phase, many vendor solutions did not integrate out of the box so that ICAM could act as policy decision point (PDP).
  6. In the EIG crawl builds, the identity and health of the resource-hosting endpoint were not checked and devices were initially joined to the network manually.
  7. Six functional use cases were demonstrated: discovery, enterprise ID, federated ID, other ID, guest and confidence level.
  8. The guide maps ZTA capabilities to NIST CSF 1.1 and 2.0, SP 800-53r5 and critical software security measures.

Using it in design

  • Write the move to zero trust into the roadmap as phases (EIG, SDP, microsegmentation) rather than a single step.
  • For management, BMS and OT network access, make separate verification of user, device and resource-hosting endpoint a design criterion.
  • Verify policy decision and enforcement point (PDP and PEP) and ICAM integrations in chosen products for out-of-the-box operation.
  • Design guest and contractor access with separate rules for no-ID and federated-ID scenarios.
  • Link selected controls to the audit file using the NIST CSF 2.0 and SP 800-53r5 mappings.

Who should read it

Data centre and enterprise network security architects, identity and access management teams and managers preparing a zero trust roadmap.

Document contents

  1. Introduction to the Guide
  2. Project Overview
  3. Architecture and Builds
  4. Build Implementation Instructions
  5. General Findings
  6. Functional Demonstrations
  7. Mappings

Publication details

Authors
Scott Rose; Oliver Borchert; Alper Kerman; Murugiah Souppaya; et al.
Publisher
NIST
Year
2025
Document number
NIST SP 1800-35
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public final-publication page inspected; author list is explicitly abbreviated as on that page. PDF transfer timed out; implementation volumes were not audited.

Citation

Scott Rose; Oliver Borchert; Alper Kerman; Murugiah Souppaya; et al. (2025). Implementing a Zero Trust Architecture: High-Level Document. NIST. NIST SP 1800-35. https://doi.org/10.6028/NIST.SP.1800-35

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.