Technical guideFree to read2024

High-Performance Computing Security: Architecture, Threat Analysis, and Security Posture (NIST SP 800-223)

Original title High-Performance Computing Security: Architecture, Threat Analysis, and Security Posture

NIST · Yang Guo, Ramaswamy Chandramouli et al.

NIST's February 2024 SP 800-223 gives a reference architecture that divides an HPC system into four functional zones (computing, data storage, access, management) and makes recommendations on network segmentation, node sanitisation and data integrity.

On this page

Overview

The publication says HPC systems differ by design, applications and missions, which impedes sharing of security solutions, and proposes an HPC reference architecture as a common lexicon. The text is a conceptual guide, not a checklist. Although HPC resembles enterprise IT, it is designed to maximise performance, so its architecture, hardware, software stack and working environment differ, and most systems serve several projects and user communities.

The reference architecture has four zones: the computing zone (compute nodes and high-speed networks), the data storage zone (parallel file system, archival and campaign storage, burst buffer), the access zone (external connectivity, authentication, session and data transfer services) and the management zone (management nodes, configuration management, scheduler and workflow). Software layers (user, site and vendor software, containers) are also defined.

Threat analysis is by zone (access, management, computing and data storage zone threats). The security posture section gives recommendations under six headings: access control through network segmentation, compute node sanitisation, data integrity protection, securing containers, achieving security while maintaining performance, and challenges for HPC security tools. Multiple physical networks are recommended for management, high-performance and auxiliary traffic.

The document is dated February 2024 and says it may be updated for new networking, storage and accelerator technologies. It is the base text on which the AI data centre security analysis (the SP 800-239 draft) builds.

Key points

  1. The reference architecture has four zones: computing, data storage, access and management.
  2. The text is a conceptual guide, not a checklist or set of mandatory requirements.
  3. HPC systems often serve several projects and user communities, creating more complex security concerns than enterprise systems.
  4. Multiple physical networks (management, high-performance, auxiliary) are highly recommended for access control and fault tolerance.
  5. The management network gives IPMI remote monitoring and control independent of CPU, firmware and OS and is open only to authorised administrators.
  6. Compute node sanitisation (end-of-job health check, GPU reset, firmware validation, reboot) is highly recommended and must be balanced against utilisation.
  7. Cryptographic mechanisms such as file- or block-level encryption provide data integrity.
  8. High-performance networks use specialised architectures such as InfiniBand, Slingshot and Omni-Path with RDMA and MPI support.

Using it in design

  • Physically separate an HPC or GPU cluster's network into management, high-performance and user networks and restrict the management network to authorised access.
  • For multi-tenant clusters, add end-of-job GPU and memory sanitisation and node health checks to operating procedure.
  • Keep the access zone (login and data transfer nodes) separate from the external network and assess risks of components such as NAT and proxies.
  • In the storage zone, design file- or block-level encryption and integrity checking.
  • Assess the performance cost of security measures in advance and set a separate policy for container security.

Who should read it

Infrastructure architects, security engineers and operations teams designing HPC and GPU clusters.

Document contents

  1. Introduction
  2. HPC System Reference Architecture and Main Components
  3. HPC Threat Analysis
  4. HPC Security Posture, Challenges, and Recommendations
  5. Conclusions
  6. Appendix A: HPC Architecture Variants

Publication details

Authors
Yang Guo; Ramaswamy Chandramouli; Lowell Wofford; Rickey Gregg; Gary Key; Antwan Clark; Catherine Hinton; Andrew Prout; Albert Reuther; Ryan Adamson; Aron Warren; Purushotham Bangalore; Erik Deumens; Csilla Farkas
Publisher
NIST
Year
2024
Document number
NIST SP 800-223
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public publisher page or document inspected. Document-specific redistribution permission was not established; metadata and original short summaries only.

Citation

Yang Guo; Ramaswamy Chandramouli; Lowell Wofford; Rickey Gregg; Gary Key; Antwan Clark; Catherine Hinton; Andrew Prout; Albert Reuther; Ryan Adamson; Aron Warren; Purushotham Bangalore; Erik Deumens; Csilla Farkas (2024). High-Performance Computing Security: Architecture, Threat Analysis, and Security Posture. NIST. NIST SP 800-223. https://doi.org/10.6028/NIST.SP.800-223

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.