nVent Hybrid Liquid Cooling: Rack-Level High-Density Cooling

Original title Maximizing Liquid Cooling Efficiencies for Advanced Level Rack Cooling

nVent SCHROFF

An nVent SCHROFF white paper presenting a rack-level Hybrid Liquid Cooling System (HLCS) that couples direct-contact liquid cooling with a rear door air-to-water heat exchanger.

On this page

Overview

The free nVent SCHROFF white paper opens by noting that content streaming, online banking, cloud computing and eCommerce are driving data processing and traffic demand. Its focus is a rack-level Hybrid Liquid Cooling System (HLCS) that pairs direct-contact liquid cooling with a rear door air-to-water heat exchanger.

According to the paper, the system is an entry point to much higher liquid-cooling efficiency and includes built-in components that give flexibility and scalability for further long-term efficiency. The stated benefits are lower energy consumption, higher rack density, lower total cost of ownership, quick and easy installation and a modular design for future upgrades.

Key points

  1. The system couples direct-contact liquid cooling with a rear door air-to-water heat exchanger.
  2. It is described as a rack-level hybrid liquid cooling system (HLCS).
  3. Stated benefits: lower energy consumption, higher rack density and lower total cost of ownership.
  4. Installation is quick and easy and the design is modular for future upgrades.

Using it in design

  • Consider pairing direct-to-chip cooling with a rear door exchanger so the heat share not captured by liquid (memory, power supplies) is handled within the rack.
  • Size primary water temperature and flow for a hybrid rack so that both heat-removal paths are covered.
  • Include modular upgrade capability in the capacity growth plan and redundancy decisions.

Who should read it

Mechanical designers and data center operators evaluating rack-level high-density liquid cooling options.

Publication details

Authors
nVent SCHROFF
Publisher
nVent SCHROFF
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Individual landing page and CoolingExpert index opened using web/TinyFish. The page states fill out the form for the free whitepaper and ©2021 nVent, all rights reserved. Template placeholders were ignored. Copyright year is not taken as publication date.

Citation

nVent SCHROFF Maximizing Liquid Cooling Efficiencies for Advanced Level Rack Cooling. nVent SCHROFF. https://go.nvent.com/uken-whitepaper-high-density-liquid-cooling.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.