Uptime Institute Intelligence, 2023, Guide or technical publication
A short Uptime Intelligence report on the resiliency questions raised as cold-plate and immersion direct liquid cooling (DLC) moves into mission-critical sites.
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
U.S. DOE Federal Energy Management Program / Lawrence Berkeley National Laboratory, 2011, Guide or technical publication
A US DOE FEMP bulletin describing how low-cost retro-commissioning at the Savannah River Site data centre cut cooling load and PUE.
Guide or technical publication
2011
Read at publisher (opens in a new tab)↗
Uptime Institute Intelligence, 2023, Guide or technical publication
An Uptime Institute Intelligence briefing report quantifying the server energy-saving potential of utilisation, refresh and power management.
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Uptime Institute Intelligence, 2022, Guide or technical publication
An Uptime Intelligence report by D. Bizo on how rising server and processor power since the mid-2010s affects air cooling and facility temperatures.
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
TMMOB Makina Mühendisleri Odası (MMO), 2019, Guide or technical publication
Özlem Karadal Güneç's TESKON 2019 paper explains how automatic suppression systems work and how they must be coordinated with architecture, HVAC and electrical systems.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
Lawrence Berkeley National Laboratory, 2026, Guide or technical publication
LBNL report reviewing the bottlenecks in connecting data centres and other large loads to the grid and organising more than 40 potential solutions into functional areas.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
SEMI-THERM, 2024, Guide or technical publication
An experimental study measuring the effect of strainer filters of different mesh sizes in the secondary loop of a direct-to-chip system on pressure drop and flow.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği (TTMD) - TTMD Dergisi, 2021, Guide or technical publication
A TTMD-published Turkish translation of an ASHRAE Journal article summarising points from the ASHRAE TC 9.9 water-cooled servers paper, covering CDU versus direct connection, dew point, water quality…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
This Qarnot presentation describes coupling 65 C rack waste heat to a silica-gel/water adsorption chiller to produce 15 C chilled water.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
TMMOB Makina Mühendisleri Odası (MMO), 2025, Guide or technical publication
Olcay Cömert's TESKON 2025 paper compares halocarbon (HFC-227ea, FK-5-1-12) and inert-gas clean-agent systems used in data centres, IT rooms and control rooms under European (EN 15004 / ISO 14520)…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Data Center Frontier (Black & Veatch contributed article), 2024, Guide or technical publication
A Black & Veatch article on the schedule, cost and reliability benefits of data centre owners building and operating their own high-voltage substations where allowed.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Data Center Knowledge, 2014, Guide or technical publication
A 2014 article by Chris Crosby arguing, from the observation that most outages stem from human error, that facilities should be designed to make mistakes harder.
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
Energy Efficient HPC Working Group / U.S. DOE FEMP, 2018, Guide or technical publication
Slides from an SC18 session with national-lab facility managers on warm-water liquid cooling, introducing a draft open specification for multi-vendor liquid-cooled racks.
Guide or technical publication
2018
Read at publisher (opens in a new tab)↗
National Institute of Standards and Technology, 2024, Guide or technical publication
NIST's framework that helps organizations of any size, sector or maturity understand, assess, prioritize and communicate cybersecurity risk. It has three components: the Core, Profiles and Tiers.
Guide or technical publication
2024
PDF
Uptime Institute, 2010, Guide or technical publication
Uptime Institute's 2009-2010 web page of Tier myths and Q&A explains that Tiers are not a checklist and are not set by component counts, utility feeds or site location.
Guide or technical publication
2010
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency (ENERGY STAR), 2023, Guide or technical publication
A one-page ENERGY STAR flyer for tenants fitting out space in a colocation facility. It covers certified IT hardware, set points, airflow management, cabling and hot-aisle/cold-aisle layout.
Guide or technical publication
2023
PDF
Çakmak Avukatlık Bürosu, 2026, Guide or technical publication
Legal briefing of 8 January 2026 on Turkish state incentives for data centres under HIT-30, the HIT-Data Centre call and Decision 9903, with their technical conditions.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Çakmak Avukatlık Bürosu, 2026, Guide or technical publication
A legal briefing of 10 February 2026 on how Turkish data centres can secure electricity: long-term power purchase agreements, unlicensed self-generation, storage and ESCO/energy performance contracts.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Data Center Frontier, 2022, Guide or technical publication
Part of a series on air cooling high-density IT, this article works through the airflow equation, required CFM versus delta-T, raised-floor tile capacity and how leakage paths undermine containment.
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
Cloudflare compares a liquid-assisted air-cooled (LAAC) 2U server, where a closed-loop cold plate dumps CPU heat to an in-chassis radiator, with the same server using a conventional heat sink. It is…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Uptime Institute, 2024, Guide or technical publication
A press release from November 2024 summarising how Uptime Institute's revised M&O Stamp of Approval evaluates data centre operations performance and staffing.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Uptime Institute, 2026, Guide or technical publication
Press release for Uptime Institute's January 2026 predictions report, summarising five trends: power shortages, onsite generation, resiliency, and AI automation.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Uptime Institute, 2017, Guide or technical publication
This September 2017 announcement introduces the TIER-Ready design review for prefabricated and modular products. Its aim is to make site-level Tier Certification faster and cheaper.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
7x24 Exchange Magazine, 2024, Guide or technical publication
A navigation article mapping the IEEE Industry Applications Society Color Books (now the IEEE 3000 I&CPS standards) onto the planning, design and construction phases of a data center electrical syste…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.