Data-centre investments in Türkiye: incentive mechanisms (Türkiye'de Veri Merkezi Yatırımları: Teşvik Mekanizmaları)

Original title Türkiye'de Veri Merkezi Yatırımları: Teşvik Mekanizmaları (Data-centre investments in Türkiye: incentive mechanisms)

Çakmak Avukatlık Bürosu · Gülşen Engin, Nazlı Başak Ayık et al.

Legal briefing of 8 January 2026 on Turkish state incentives for data centres under HIT-30, the HIT-Data Centre call and Decision 9903, with their technical conditions.

On this page

Overview

This legal briefing by Çakmak Avukatlık Bürosu, dated 8 January 2026, summarises Turkish state incentives for data centres under the HIT-30 project-based programme, its October 2025 HIT-Data Centre call, and the Priority and Target investment schemes of Decision 9903. The incentives come with hard technical conditions, which translate directly into design targets for Turkish projects. The HIT-Data Centre call (17 October 2025) offers about $1.5 bn of support and requires at least 30 MW IT capacity, at least 50% AI-hardware-ready capacity, PUE of 1.4 or lower and integration with major cloud and AI service centres.

HIT-30 supports require a minimum fixed investment of TRY 2 bn; incentives include up to 50% tax incentive and energy support of up to 10% of the investment. The Decision 9903 schemes require a TSE Data Centre Design Certificate under TS EN 50600 with minimum Availability Class 3, Protection Class 4 and Energy Granularity Level 3.

Also required are a full-occupancy PUE of at most 1.65 (no partial calculation) and fibre from at least two telecom operators terminating in the data centre; a TSE Data Centre Facility Certificate follows completion. The Priority Investment scheme needs at least 3 MW installed power (60% tax reduction up to a 30% investment contribution rate), and the Target scheme at least 500 kW (20% contribution rate). This is a legal summary; current legislation and the call text must be verified before applying.

Key points

  1. HIT-Data Centre call (17 Oct 2025): about $1.5 bn support; at least 30 MW IT capacity, at least 50% AI-hardware-ready capacity, PUE 1.4 or lower and integration with major cloud/AI service centres.
  2. HIT-30 supports require minimum fixed investment of TRY 2 bn; up to 50% tax incentive and energy support up to 10% of investment.
  3. Decision 9903 schemes require a TSE Data Centre Design Certificate under TS EN 50600 with minimum Availability Class 3, Protection Class 4 and Energy Granularity Level 3.
  4. Full-occupancy PUE of at most 1.65 (no partial calculation).
  5. Fibre from at least two telecom operators terminating in the data centre; TSE Data Centre Facility Certificate after completion.
  6. Priority Investment scheme: at least 3 MW installed power (60% tax reduction up to a 30% investment contribution rate).
  7. Target scheme: at least 500 kW (20% contribution rate).

Using it in design

  • Add a 'Türkiye incentive compliance' check: TS EN 50600 AC≥3, PC≥4, GL≥3.
  • Verify design PUE of at most 1.65 at full load (at most 1.4 for HIT-Data Centre).
  • Check for at least two diverse telecom fibre entries and the capacity thresholds (0.5 / 3 / 30 MW).
  • Show pass/fail in the design report.

Who should read it

Developers, investors and engineers planning data centre investments in Türkiye who need design targets for incentive compliance.

Related standards

  • TS EN 50600
  • EN 50600-2-1
  • EN 50600-4-2

Publication details

Authors
Gülşen Engin; Nazlı Başak Ayık; Gürem Ulusoy
Publisher
Çakmak Avukatlık Bürosu
Year
2026
Document language
Turkish
Source type
Expert / community
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document

Citation

Gülşen Engin; Nazlı Başak Ayık; Gürem Ulusoy (2026). Türkiye'de Veri Merkezi Yatırımları: Teşvik Mekanizmaları (Data-centre investments in Türkiye: incentive mechanisms). Çakmak Avukatlık Bürosu. https://cakmak.av.tr/wp-content/uploads/2026/01/Turkiyede-Veri-Merkezi-Yatirimlari.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.