Uptime Institute TIER-Ready Program for Prefabricated and Modular Data Centers - press release

Uptime Institute

This September 2017 announcement introduces the TIER-Ready design review for prefabricated and modular products. Its aim is to make site-level Tier Certification faster and cheaper.

On this page

Overview

The announcement describes the TIER-Ready design review launched by Uptime Institute for prefabricated and modular data center products. The program lets manufacturers have the design of pre-built modular solutions validated before site deployment. A product therefore arrives with a measure of design assurance, which reduces the effort needed for the eventual Tier Certification. The record is held as a press release dated September 2017.

The release names Schneider Electric, Compass Datacenters and Huawei among the initial participants. In its testimonial, Compass refers to 1.2 MW blocks validated under TIER-Ready. The example shows the modular approach resting on a repeatable validation model built around unit capacity blocks. The text is a commercial announcement and does not detail the technical criteria or the review method.

The release also states that Tier Certified data centers perform predictably under a wide range of conditions, including complete utility power failure. That wording underlines the value of certification, but it is equally clear that product-level TIER-Ready validation does not replace a site-level check of topology.

Key points

  1. TIER-Ready validates the design of pre-built modular solutions before site deployment.
  2. The goal is faster, cheaper site Tier Certification.
  3. Initial suppliers included Schneider Electric, Compass Data Centers and Huawei.
  4. Compass cited 1.2 MW blocks validated under TIER-Ready.
  5. Tier Certified data centers are described as performing predictably under a wide range of conditions, including complete utility power failure.
  6. The announcement is dated September 2017 and is a press release.

Using it in design

  • Verify and record the prefabricated module’s TIER-Ready (Uptime) status from product documentation.
  • Do not treat TIER-Ready status as a substitute for a site-level topology check; still require that review.
  • Specify block capacity explicitly in modular designs, for example 1.2 MW.
  • Treat validated-design status as a separate criterion when comparing suppliers.

Who should read it

Designers selecting prefabricated or modular data center products, suppliers, and project teams planning certification.

Publication details

Authors
Uptime Institute
Publisher
Uptime Institute
Year
2017
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Publisher press release / public web page; copyright Uptime Institute, no open licence. Citation only.

Citation

Uptime Institute (2017). Uptime Institute TIER-Ready Program for Prefabricated and Modular Data Centers - press release. Uptime Institute. https://uptimeinstitute.com/about-ui/press-releases/tier-ready-program-for-prefabricated-and-modular-data-centers

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.