Technical guideFree to readYear not stated

Two-phase direct contact liquid cooling ecosystem: Configurable to your data center density needs

Parker Hannifin / ZutaCore

A joint Parker Hannifin and ZutaCore application paper describing a two-phase cold-plate ecosystem and the roles of heat rejection, refrigerant distribution and workload-aware control.

On this page

Overview

The paper is a joint application paper describing a two-phase cold-plate ecosystem and the roles of heat rejection, refrigerant distribution and workload-aware control. The rack architecture includes a heat rejection unit and a refrigerant distribution unit connected to servers.

The paper describes software control that relates processing and cooling parameters.

Key points

  1. A two-phase cold-plate ecosystem is described.
  2. The rack architecture includes a heat rejection unit and a refrigerant distribution unit.
  3. The heat rejection and distribution units connect to servers.
  4. Software control relates processing and cooling parameters.

Using it in design

  • In two-phase cold-plate design plan the heat rejection unit and refrigerant distribution unit as separate components in the rack architecture.
  • For workload-aware control define the data interface between processing and cooling parameters and the BMS.
  • Configure the ecosystem to density needs by server and rack count.

Who should read it

Designers evaluating two-phase direct contact cooling architectures.

Publication details

Authors
Parker Hannifin / ZutaCore
Publisher
Parker Hannifin / ZutaCore
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public manufacturer source inspected. No document-specific redistribution permission established. Metadata and original brief summaries only; local downloads are research evidence, not a redistribution package.

Citation

Parker Hannifin / ZutaCore Two-phase direct contact liquid cooling ecosystem: Configurable to your data center density needs. Parker Hannifin / ZutaCore. https://www.parker.com/content/dam/parker/fcg/group/data-centers/Parker%20Data%20Center%20Cooling%20White%20Paper.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.