Research paperFree to read2026

A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT-Cooling Divide

Original title A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide

Energies (MDPI AG) · Mouna Nassim, Mohamed Bezza

Energies (MDPI) 2026 review: across 45 studies, AI energy reductions have a median of about 9% for cooling, 13% for ICT and 16-17% for whole facilities, and no study reports closed-loop production deployment.

On this page

Overview

The review examines how AI is applied to cooling, to ICT resources and to the data centre as a whole (Full-DC). The authors call the habit of optimising IT and cooling as two separate problems the IT-cooling divide. Scopus and Web of Science were searched for 2021-2025 journal articles reporting quantitative results, following PRISMA 2020; 45 studies were selected (16 cooling, 21 ICT, 8 Full-DC). Because selection was made by a single reviewer, the reported shares describe the reviewed sample, and reinforcement learning is over-represented in it.

On findings, reinforcement learning is the most frequent primary approach for control and deep learning for prediction. Energy results are heterogeneous: they use different baselines (PID control, heuristics, competing algorithms), different reporting levels (cooling plant, IT servers, network, facility) and come almost entirely from simulation, trace-driven or offline evaluation. Among studies reporting a percentage energy reduction, the median is about 9% for cooling (n = 7) and 13% for ICT (n = 7), and 16-17% for the two Full-DC studies. Only two studies explicitly co-optimise computing and cooling decisions; joint IT-cooling optimisation remains promising but thinly tested.

Key points

  1. 45 studies were reviewed: 16 cooling, 21 ICT, 8 Full-DC; publications from 2021-2025.
  2. Median energy reduction is about 9% for cooling (n = 7) and about 13% for ICT (n = 7); 16-17% in the two Full-DC studies.
  3. No study reports closed-loop deployment in production; results are simulation, trace-driven or offline.
  4. Baselines and reporting levels differ, which limits comparison across studies.
  5. Reinforcement learning is the most frequent approach for control and deep learning for prediction; selection was by a single reviewer.
  6. Only two studies co-optimise computing and cooling decisions.

Using it in design

  • When AI-based cooling control claims energy savings, question the baseline (PID, heuristic) and the reporting level (plant or facility).
  • In control system specifications, look for a production-validated closed-loop reference; according to the review the literature has none.
  • Design the data interface between the BMS and the IT scheduler (temperature, workload forecast) to be ready for joint optimisation.
  • Build facility-level metering and reporting so real-world validation can be done later.

Who should read it

Engineers, researchers and decision makers evaluating AI solutions for data-centre cooling control and operations optimisation.

Publication details

Authors
Mouna Nassim; Mohamed Bezza
Publisher
Energies (MDPI AG)
Year
2026
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher copyright/rights statement explicitly grants CC BY; version 4.0 is corroborated by publisher-deposited Crossref license metadata. Third-party material may have separate rights. Round 3/4 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Mouna Nassim; Mohamed Bezza (2026). A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide. Energies (MDPI AG). https://doi.org/10.3390/en19225417

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace