Schneider Electric Marketplace's transfer switch page lists APC NetShelter Rack ATS models (1U and 2U; 10-32 A; 100-240 V), AP4430A to AP4453A, with input plug and output outlet configurations.

On this page

Overview

The page lists rack-mount transfer switches in the transfer switch category of the Schneider Electric US marketplace. Each row gives an APC NetShelter Rack Automatic Transfer Switch (ATS) model's height (1U or 2U), current, voltage, input plug, output outlet type and availability. The models select between two input sources to give redundant power to single-corded IT equipment in a rack.

Available models listed: AP4453A (2U, 30 A, 120 V, 2 x L5-30P in, 16 x 5-20R out), AP4452A (1U, 20 A, 120 V, 2 x L5-20 in, 10 x 5-20R out), AP4434A (1U, 20 A, 208 V, 2 x C20 in, 8 x C13 and 1 x C19 out), AP4433A (1U, 12 A, 208 V, C14 in, 12 x C13 out), AP4432A (2U, 30 A, 200/208 V, 2 x L6-30 in, 16 x C13 and 2 x C19 out), AP4431A (2U, 30 A, 208 V, 2 x L6-30P in, 1 x L6-30R out) and AP4430A (1U, 20 A, 200/208 V, 2 x L6-20 in, 8 x C13 and 1 x C19 out). A cord retention bracket (AP7769) and rear rail bracket kit (AP7768) are accessories.

Unavailable models include AP4450A (1U, 15 A, 100/120 V), AP4424A (2U, 32 A, 230 V, 2 x IEC 309 in, 16 x C13 and 2 x C19 out), AP4423A (1U, 16 A, 230 V, 2 x C20 in), AP4421A (1U, 10 A, 230 V, C14 in, 12 x C13 out) and AP4422A (1U, 16 A, 230 V, 2 x IEC309 in and out). All models are 50/60 Hz. The page is a catalogue list and does not give detailed technical values such as transfer time.

Key points

  1. APC NetShelter Rack ATS: 1U and 2U height; 10, 12, 15, 16, 20, 30 and 32 A options.
  2. Voltage classes: 100/120 V, 200/208 V, 208 V and 230 V; all 50/60 Hz.
  3. AP4453A: 2U, 30 A, 120 V, 2 x L5-30P in, 16 x 5-20R out.
  4. AP4432A: 2U, 30 A, 200/208 V, 2 x L6-30 in, 16 x C13 and 2 x C19 out.
  5. AP4434A: 1U, 20 A, 208 V, 2 x C20 in, 8 x C13 and 1 x C19 out.
  6. AP4433A: 1U, 12 A, 208 V, C14 in, 12 x C13 out.
  7. 230 V models: AP4424A (2U, 32 A, IEC 309 in), AP4423A (1U, 16 A), AP4421A (1U, 10 A, 12 x C13), AP4422A (1U, 16 A, IEC309 out).
  8. Accessories: cord retention bracket AP7769, rear rail bracket kit AP7768.

Using it in design

  • To connect single-corded IT equipment to two sources, select the ATS for the rack's voltage class (120, 208 or 230 V) and total current.
  • Match output outlet type and count (C13 and C19) to the rack equipment list; the input plug type (L5, L6, C14, C20, IEC 309) must fit the two PDU feeds to the rack.
  • Record in the design document that the rack's A and B feeds come from different phases or UPS systems and that the ATS is a single point of failure.
  • Put the 1U and 2U heights and the bracket kit into the rack U plan; include availability in the procurement plan.

Who should read it

IT infrastructure and electrical engineers designing rack-level redundant power.

Document contents

  1. Category: rack-mount transfer switches
  2. Available models
  3. Unavailable models
  4. Accessories

Publication details

Authors
Schneider Electric
Publisher
Schneider Electric
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Schneider Electric Schneider Electric Marketplace transfer switch catalogue. Schneider Electric. https://shop.se.com/pro/us/en/category/transfer-switches-13157/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.