Research paperFree to read2023

GEECO: Green Data Centers for Energy Optimization and Carbon Footprint Reduction

Sustainability (MDPI AG) · Sudipto Mondal, Fashat Bin Faruk et al.

The 2023 Sustainability article (DOI 10.3390/su152115249) proposes the GEECO model, which adjusts workload distribution and task assignment dynamically to cut energy use and carbon emissions in cloud data centres.

On this page

Overview

The article proposes the Green Energy Efficiency and Carbon Optimization (GEECO) model to reduce energy use and carbon emissions in cloud-computing data centres. The model dynamically adjusts workload distribution and task assignment within the data centre to balance performance and service-level reconciliation. Real-time monitoring of energy use and workload demand allows energy-optimisation and carbon-reduction opportunities to be identified.

The authors report that the results show a considerable increase in energy efficiency, with significant decreases in energy use and costs, and that the model improves energy consumption and carbon emissions in the different scenarios introduced; the resilience and practicality of the solution are also analysed. The reported scenario comparisons illustrate scheduling choices and are not a facility commissioning method. The journal is Sustainability (MDPI), DOI 10.3390/su152115249.

Key points

  1. The GEECO model adjusts workload distribution and task assignment dynamically.
  2. The model balances performance and service-level reconciliation.
  3. Energy use and workload demand are monitored in real time.
  4. Results show reductions in energy consumption and carbon emissions in different scenarios.
  5. The resilience and practicality of the solution are analysed.
  6. Journal is Sustainability (MDPI), 2023, DOI 10.3390/su152115249.

Using it in design

  • In multi-site or cloud environments, include an energy- and carbon-aware workload placement rule in the operating design.
  • Design real-time energy and workload telemetry so that it feeds scheduling decisions.
  • Define service-level agreements together with energy-driven scheduling constraints.
  • Use the paper's results as an example of scheduling options, not as a facility commissioning method.

Who should read it

Engineers and researchers working on energy- and carbon-aware workload management in cloud data centres.

Publication details

Authors
Sudipto Mondal; Fashat Bin Faruk; Dibosh Rajbongshi; Mohammad Masum Khondhoker Efaz; Md. Motaharul Islam
Publisher
Sustainability (MDPI AG)
Year
2023
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher copyright/rights statement explicitly grants CC BY; version 4.0 is corroborated by publisher-deposited Crossref license metadata. Third-party material may have separate rights. Round 3/4 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Sudipto Mondal; Fashat Bin Faruk; Dibosh Rajbongshi; Mohammad Masum Khondhoker Efaz; Md. Motaharul Islam (2023). GEECO: Green Data Centers for Energy Optimization and Carbon Footprint Reduction. Sustainability (MDPI AG). https://doi.org/10.3390/su152115249

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.