Modeling Critical Success Factors for Green Energy Integration in Data Centers

Sustainability (MDPI AG) · Panos T. Chountalas, Stamatios K. Chrysikopoulos et al.

A 2025 Sustainability paper that identifies eleven critical success factors for green energy adoption in data centres through literature review and expert validation and maps their interdependencies with DEMATEL; governance and investment strategy are most influential.

On this page

Overview

The paper identifies and analyses the critical success factors (CSFs) affecting the integration of green energy solutions in data centres, given rising energy demand and sustainability requirements, covering both technical and organisational challenges. It is published in Sustainability (MDPI).

A systematic literature review and expert validation yield eleven CSFs, including energy efficiency, renewable energy integration, carbon neutrality strategies, regulatory compliance and investment strategies. Interdependencies are analysed with the DEMATEL method. According to the findings, governance and organisational culture and investment strategy are the most influential CSFs; carbon neutrality strategies are the mediating factor linking governance and financial commitment to operational sustainability outcomes. Renewable energy integration and regulatory compliance act as structural mediators. The results give operators, policymakers and stakeholders a prioritisation roadmap.

Key points

  1. Eleven critical success factors are identified.
  2. Method: systematic literature review, expert validation and causal mapping with DEMATEL.
  3. Governance and organisational culture and investment strategy are the most influential CSFs.
  4. Carbon neutrality strategies are the mediating factor linking governance and financial commitment to operational sustainability.
  5. Renewable energy integration and regulatory compliance are structural mediators.

Using it in design

  • In green energy integration projects, settle governance and investment strategy decisions before technical design.
  • Prepare a roadmap tying carbon neutrality targets to financing and operating indicators.
  • Add regulatory compliance and renewable energy supply to the project risk register as separate items.
  • Use the DEMATEL results as an expert-opinion-based prioritisation input.

Who should read it

Data centre sustainability and energy strategy managers, policymakers and investment decision makers.

Publication details

Authors
Panos T. Chountalas; Stamatios K. Chrysikopoulos; Konstantina K. Agoraki; Natalia Chatzifoti
Publisher
Sustainability (MDPI AG)
Year
2025
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher copyright/rights statement explicitly grants CC BY; version 4.0 is corroborated by publisher-deposited Crossref license metadata. Third-party material may have separate rights. Round 3/4 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Panos T. Chountalas; Stamatios K. Chrysikopoulos; Konstantina K. Agoraki; Natalia Chatzifoti (2025). Modeling Critical Success Factors for Green Energy Integration in Data Centers. Sustainability (MDPI AG). https://doi.org/10.3390/su17083543

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.