Optimization Control Strategies and Evaluation Metrics of Cooling Systems in Data Centers: A Review

Sustainability (MDPI AG) · Qiankun Chang, Yuanfeng Huang et al.

A 2024 Sustainability review uses CiteSpace on Scopus, Web of Science and IEEE literature to map data center cooling classification, control optimization and energy metrics, and urges wider AI use and global metric standardization.

On this page

Overview

The review notes that although many studies address classification and optimization of data center cooling systems, systematic reviews using bibliometric methods are scarce. Using CiteSpace and the Scopus, Web of Science and IEEE databases, it maps the field's historical development and current trends.

Findings show that current focal points are cooling system classification, optimization strategies and energy efficiency metrics. The review assesses the applicability of air-cooled and liquid-cooled systems in different operating environments and offers practical guidance for selection. For air cooling, optimizing the design of static pressure chamber baffles is shown to improve airflow uniformity significantly.

The conclusion advocates expanding the use of artificial intelligence and machine learning to automate data collection and energy efficiency analysis, and calls for global standardization of energy efficiency metrics.

Key points

  1. Method: bibliometric analysis with CiteSpace of Scopus, Web of Science and IEEE literature.
  2. Current focal points: cooling system classification, optimization strategies and energy efficiency metrics.
  3. The applicability of air-cooled and liquid-cooled systems in different operating environments is assessed.
  4. In air cooling, static pressure chamber baffle design significantly improves airflow uniformity.
  5. AI and machine learning are advocated for data collection and efficiency analysis; global standardization of energy metrics is requested.

Using it in design

  • When choosing a cooling concept, compare the applicability limits of air and liquid cooling against the review's classification.
  • In air-cooled designs, check with CFD how raised-floor plenum baffles and guides affect airflow uniformity.
  • In monitoring design, state clearly in reports the definition differences between efficiency metrics (PUE and others).
  • Plan AI-based control optimization together with the data collection infrastructure.

Who should read it

Researchers and designers surveying the literature on data center cooling control and efficiency metrics.

Publication details

Authors
Qiankun Chang; Yuanfeng Huang; Kaiyan Liu; Xin Xu; Yaohua Zhao; Song Pan
Publisher
Sustainability (MDPI AG)
Year
2024
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher copyright/rights statement explicitly grants CC BY; version 4.0 is corroborated by publisher-deposited Crossref license metadata. Third-party material may have separate rights. Round 3/4 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Qiankun Chang; Yuanfeng Huang; Kaiyan Liu; Xin Xu; Yaohua Zhao; Song Pan (2024). Optimization Control Strategies and Evaluation Metrics of Cooling Systems in Data Centers: A Review. Sustainability (MDPI AG). https://doi.org/10.3390/su16167222

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace