Shenling Liquid Cooling CDU Range
Original title Liquid Cooling CDU
Guangdong Shenling
Shenling's liquid cooling CDU page presents CDUs of 200-1800 kW for cold-plate and immersion systems, supporting cabinets up to 140 kW and targeting PUE of 1.15 or below.
On this page
Overview
Guangdong Shenling Environment Systems offers CDUs for cold-plate liquid-cooled servers and immersion liquid cooling systems (tank or rack). According to the page the unit suits sites with few geographic constraints, reaches PUE of 1.15 or below and mainly targets AI data centres and intelligent computing centres.
Cooling capacity runs from 200 to 1800 kW and supports high-density cabinets up to 140 kW. A fully variable-frequency system with variable-frequency pumps and distribution regulation gives adaptive operation, and high compatibility with cold plate, immersion and spray liquid cooling is stated. The page is a range overview, not a model selection sheet; model codes and external dimensions are not listed.
Key points
- Capacity range is 200-1800 kW.
- Cabinet density up to 140 kW is supported.
- PUE of 1.15 or below is targeted.
- Compatible with cold-plate, immersion (tank and rack) and spray liquid cooling.
- Fully variable-frequency pumps and distribution regulation give adaptive operation.
Using it in design
- If AI cabinet density reaches 140 kW, compare CDU capacity with that upper limit and the site total.
- The page has no model code or dimension, so obtain size, pipe connection and electrical input from the manufacturer.
- Match the fluid temperature need of cold-plate and immersion systems to the CDU primary and secondary circuit design.
- Verify the PUE 1.15 target together with load level and outdoor conditions.
Who should read it
Mechanical designers selecting CDUs for AI and high-density data centres.
Publication details
- Authors
- Guangdong Shenling
- Publisher
- Guangdong Shenling
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Guangdong Shenling Liquid Cooling CDU. Guangdong Shenling. https://www.shenling.com/en/products/liquid-cooled-temperature-control-products/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.